The three-phase independent adjustable RCD nonlinear load bank is designed to accurately test and evaluate power systems under diverse load conditions. Its ability to independently adjust each phase ensures precise simulation of real-world scenarios, enhancing the reliability and performance of generators and UPS systems. This advanced load bank accommodates nonlinear loads, making it ideal for testing modern power equipment and ensuring compliance with industry standards.
Availability: | |
---|---|
Quantity: | |
Product Description:
Ensure your power systems meet peak performance with the three-phase independent adjustable RCD nonlinear load bank. Whether testing inverters or conducting UPS load tests, its comprehensive capabilities provide unparalleled reliability and data accuracy. Ideal for both lab and field applications, this load bank is your trusted partner in safeguarding critical power infrastructure, offering precise control and robust performance for demanding testing requirements.
Product Features&Advantage:
1.Suitable for testing inverters and UPS loads.
2.Includes upper computer operating software, compatible with ATE special envoy.
3.Equipped with RS485, Ethernet, CAN, and other communication ports.
4.Features programmable test steps, ideal for automatic testing of photovoltaic and energy storage inverters.
5.Capable of loading any power within the full power range.
6.Power adjustment precision: as low as 10W.
7.Power factor adjustment: as low as 0.45.
8.Peak factor CF: up to 3.
9.Customizable for a wide voltage range.
10.Utilizes PC data management software to control load operations and save test data.
Product Description:
Ensure your power systems meet peak performance with the three-phase independent adjustable RCD nonlinear load bank. Whether testing inverters or conducting UPS load tests, its comprehensive capabilities provide unparalleled reliability and data accuracy. Ideal for both lab and field applications, this load bank is your trusted partner in safeguarding critical power infrastructure, offering precise control and robust performance for demanding testing requirements.
Product Features&Advantage:
1.Suitable for testing inverters and UPS loads.
2.Includes upper computer operating software, compatible with ATE special envoy.
3.Equipped with RS485, Ethernet, CAN, and other communication ports.
4.Features programmable test steps, ideal for automatic testing of photovoltaic and energy storage inverters.
5.Capable of loading any power within the full power range.
6.Power adjustment precision: as low as 10W.
7.Power factor adjustment: as low as 0.45.
8.Peak factor CF: up to 3.
9.Customizable for a wide voltage range.
10.Utilizes PC data management software to control load operations and save test data.
Name | Three-Phase RCD load - Nonlinear load | |||||
Model | IMAX5330-15k | IMAX5330-30k | IMAX5330-45k | IMAX5330-60k | IMAX3510-100k | IMAX3510-200k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V | |||||
Working Voltage | Other voltages, wide voltages, or other mode can be customized | |||||
Max Power | 15kVA | 30kVA | 45kVA | 60kVA | 100kVA | 200kVA |
Rated Frequency | 50/60Hz | |||||
Power Factor (PF) | 0.6~1 adjustable,0.5 at least | |||||
Crest Factor(CF) | 2~3adjustable | |||||
Step accuracy | 100W/50W/25W Optional | |||||
Load classification
| A Phase:0.1k/0.2k/0.5k/1k/2k/5k/other | |||||
B Phase:0.1k/0.2k/0.5k/1k/2k/5k/other | ||||||
C Phase:0.1k/0.2k/0.5k/1k/2k/5k/other | ||||||
Customizable: three single-phase/one single-phase/three-phase independent, maximum power does not exceed total power | ||||||
Load Function | R load test, RCD load test, total load switch, short circuit function is optional | |||||
Main Testing Items | Portable energy storage power supply, outdoor energy storage power supply, home energy storage power supply, photovoltaic inverter load test, UPS power supply test, other nonlinear load test requirements | |||||
Protection Alarm | Ground protection, high temperature fault, emergency stop and other protection functions. | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | |||||
Noise | ≤72dB | ≤75dB | ≤78dB | |||
Air Outlet Mode | Wind in from the side down and out from the top. | |||||
Display Accuracy | 0.1V,0.1A,PF(0.01) | |||||
Control Mode | Manual: Button/circuit breaker control | |||||
Local manual control: through 7 inch LCD touch screen of load bank | ||||||
Remote intelligent control: RS485, (the protocol is Modbus-RTU, and the upper computer software is provided.) | ||||||
Place of Use | Indoor | Indoor/Outdoor | ||||
Weight | 150kg | 230kg | 280kg | 320kg | 400kg | 480kg |
Size | W800mm×D600mm×H1600mm | W1000mm×D1200mm×H1850mm | W1200mm×D1400mm×H2000mm |
Name | Single-phase RCD load | ||
Model | IMAX5310-5k | IMAX5310-10k | IMAX3510-15k |
Rated Voltage | 1P2W,220V/110V,Double voltage can be customized | ||
Max Power | 5kVA | 10kVA | 15kVA |
Rated Frequency | 50/60Hz | ||
Power Factor (PF) | 0.6~1(adjustable),0.45 at least | ||
Crest Factor(CF) | 2~3 | ||
Step accuracy | 100W/50W/25W Optional | ||
Load classification | 0.1k/0.2k/0.5k/1k/2k/5k/other | ||
Main Testing Items | Portable energy storage power supply, outdoor energy storage power supply, home energy storage power supply, photovoltaic inverter load test, UPS power supply test, other nonlinear load test requirements | ||
Protection Alarm | Ground protection, high temperature fault, emergency stop and other protection functions. | ||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | ||
Noise | ≤65dB | ≤70dB | ≤70dB |
Air Outlet Mode | Wind in from the front, out from the behind | Wind in from the side down and out from the top | Wind in from the side down and out from the top |
Display Accuracy | 0.1V,0.1A | ||
Control Mode | Manual: Button/circuit breaker control | ||
Local manual control: through 7 inch LCD touch screen of load bank | |||
Remote intelligent control: RS485, (the protocol is Modbus-RTU, and the upper computer software is provided.) |
Name | Three-Phase RCD load - Nonlinear load | |||||
Model | IMAX5330-15k | IMAX5330-30k | IMAX5330-45k | IMAX5330-60k | IMAX3510-100k | IMAX3510-200k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V | |||||
Working Voltage | Other voltages, wide voltages, or other mode can be customized | |||||
Max Power | 15kVA | 30kVA | 45kVA | 60kVA | 100kVA | 200kVA |
Rated Frequency | 50/60Hz | |||||
Power Factor (PF) | 0.6~1 adjustable,0.5 at least | |||||
Crest Factor(CF) | 2~3adjustable | |||||
Step accuracy | 100W/50W/25W Optional | |||||
Load classification
| A Phase:0.1k/0.2k/0.5k/1k/2k/5k/other | |||||
B Phase:0.1k/0.2k/0.5k/1k/2k/5k/other | ||||||
C Phase:0.1k/0.2k/0.5k/1k/2k/5k/other | ||||||
Customizable: three single-phase/one single-phase/three-phase independent, maximum power does not exceed total power | ||||||
Load Function | R load test, RCD load test, total load switch, short circuit function is optional | |||||
Main Testing Items | Portable energy storage power supply, outdoor energy storage power supply, home energy storage power supply, photovoltaic inverter load test, UPS power supply test, other nonlinear load test requirements | |||||
Protection Alarm | Ground protection, high temperature fault, emergency stop and other protection functions. | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | |||||
Noise | ≤72dB | ≤75dB | ≤78dB | |||
Air Outlet Mode | Wind in from the side down and out from the top. | |||||
Display Accuracy | 0.1V,0.1A,PF(0.01) | |||||
Control Mode | Manual: Button/circuit breaker control | |||||
Local manual control: through 7 inch LCD touch screen of load bank | ||||||
Remote intelligent control: RS485, (the protocol is Modbus-RTU, and the upper computer software is provided.) | ||||||
Place of Use | Indoor | Indoor/Outdoor | ||||
Weight | 150kg | 230kg | 280kg | 320kg | 400kg | 480kg |
Size | W800mm×D600mm×H1600mm | W1000mm×D1200mm×H1850mm | W1200mm×D1400mm×H2000mm |
Name | Single-phase RCD load | ||
Model | IMAX5310-5k | IMAX5310-10k | IMAX3510-15k |
Rated Voltage | 1P2W,220V/110V,Double voltage can be customized | ||
Max Power | 5kVA | 10kVA | 15kVA |
Rated Frequency | 50/60Hz | ||
Power Factor (PF) | 0.6~1(adjustable),0.45 at least | ||
Crest Factor(CF) | 2~3 | ||
Step accuracy | 100W/50W/25W Optional | ||
Load classification | 0.1k/0.2k/0.5k/1k/2k/5k/other | ||
Main Testing Items | Portable energy storage power supply, outdoor energy storage power supply, home energy storage power supply, photovoltaic inverter load test, UPS power supply test, other nonlinear load test requirements | ||
Protection Alarm | Ground protection, high temperature fault, emergency stop and other protection functions. | ||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | ||
Noise | ≤65dB | ≤70dB | ≤70dB |
Air Outlet Mode | Wind in from the front, out from the behind | Wind in from the side down and out from the top | Wind in from the side down and out from the top |
Display Accuracy | 0.1V,0.1A | ||
Control Mode | Manual: Button/circuit breaker control | ||
Local manual control: through 7 inch LCD touch screen of load bank | |||
Remote intelligent control: RS485, (the protocol is Modbus-RTU, and the upper computer software is provided.) |