Availability: | |
---|---|
Quantity: | |
IMAX3305-600KW
EMAX
Perfect for industries requiring regular power testing and validation, this load bank ensures that your equipment is performing at optimal levels without risks of overloading or downtime during routine checks.
Power Capacity: 600KW, scalable for flexible testing
Voltage Range: 3P4W,AC230V/220V/110V
Load Steps: Precise incremental load steps for enhanced control
Cooling System: Forced air cooling with temperature monitoring
Control Panel: Digital, local or remote control options
Safety Protections: Overheat, overvoltage, and overload protection
Portable Design: Compact with robust construction and forklift-ready frame
Data Logging: Real-time load data and results logging
Testing of diesel generators, gas turbines, and renewable energy systems
UPS and battery system commissioning and testing
Data center backup power validation
Routine load testing in commercial and industrial facilities
Power grid maintenance and simulation
The 600KW AC Low Voltage Load Bank offers unparalleled performance for rigorous load testing. Designed for both indoor and outdoor use, it is built to withstand harsh environments while ensuring safety and efficiency. With precise load control and robust safety mechanisms, this load bank maximizes testing accuracy and operational reliability.
For more details or to request a quote, please contact our sales team:
Phone: +86-15099752515
Email: saleszhou@i-maix.com
Perfect for industries requiring regular power testing and validation, this load bank ensures that your equipment is performing at optimal levels without risks of overloading or downtime during routine checks.
Power Capacity: 600KW, scalable for flexible testing
Voltage Range: 3P4W,AC230V/220V/110V
Load Steps: Precise incremental load steps for enhanced control
Cooling System: Forced air cooling with temperature monitoring
Control Panel: Digital, local or remote control options
Safety Protections: Overheat, overvoltage, and overload protection
Portable Design: Compact with robust construction and forklift-ready frame
Data Logging: Real-time load data and results logging
Testing of diesel generators, gas turbines, and renewable energy systems
UPS and battery system commissioning and testing
Data center backup power validation
Routine load testing in commercial and industrial facilities
Power grid maintenance and simulation
The 600KW AC Low Voltage Load Bank offers unparalleled performance for rigorous load testing. Designed for both indoor and outdoor use, it is built to withstand harsh environments while ensuring safety and efficiency. With precise load control and robust safety mechanisms, this load bank maximizes testing accuracy and operational reliability.
For more details or to request a quote, please contact our sales team:
Phone: +86-15099752515
Email: saleszhou@i-maix.com
Name | Single phase pure resistance load -R | ||
Model | IMAX3110-30k | IMAX3305-500k | IMAX3305-600k |
Rated Voltage | 3P4W,AC230V/220V/110V | ||
Resistive Power | 33kW | 500kW | 6000kW |
Rated Frequency | 50/60Hz | 50/60Hz | 50/60Hz |
Loading Mode | Step and shift loading | ||
Load Characteristic | Pure Resistance | ||
Load Stepping | The minimum resistance step size is 1kW | ||
Main test items | Power supply detection long - term load, switching device life test | ||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | ||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | ||
Noise | ≤70dB | ≤73dB | ≤75dB |
Air Outlet Mode | Side wind in, side wind out | Wind in from the side down and out from the top. | |
Display Accuracy | 0.1V,0.1A | ||
Control Mode | Local manual control: Local button/air switch/touch screen control | ||
Remote intelligent control: RS485/CAN/ Ethernet | |||
Place of Use | Indoor | ||
Weight | 50kg | 75kg | 150kg |
Size | W600mm×D800mm×H800mm | W600mm×D800mm×H1400mm | W600mm×D800mm×H1600mm |
Name | Three-phase pure resistance load -R | |||||
Model | IMAX3130-50k | IMAX3130-100k | IMAX3130-300k | IMAX3130-500k | IMAX3130-700k | IMAX3130-1000k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V | |||||
Resistive Power | 55kW | 110kW | 310kW | 510kW | 710kW | 1030kW |
Rated Frequency | 50/60Hz | |||||
Loading Mode | Step loading | |||||
Load Characteristic | pure resistance | |||||
Load Stepping | The minimum step size of the resistance divider is 10W | |||||
Main test items | Power supply detection long - term load, switching device life test | |||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | |||||
Noise | ≤75dB | ≤79dB | ≤82dB | |||
Air Outlet Mode | Wind in from the side down and out from the top | Side down ejection/side in side out | Wind in from the side down and out from the top | |||
Display Accuracy | 0.1V,0.1A | |||||
Control Mode | Local manual control: local button/circuit breaker | Local manual control: through the load box 7 inch LCD touch screen. | ||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||||
Place of Use | Indoor | Indoor/Outdoor | ||||
Weight | 80kg | 120kg | 450kg | 650kg | 950kg | 1300kg |
Size | W600mm×D800mm×H1400mm | W600mm×D800mm×H1600mm | sideward :W1500mm×D1300mm×H1400mm ejection:W1200mm*D1200mm*1800mm | sideward :W1750mm×D1300mm×H1400mm | W1200mm×D1400mm×H2000mm | W1800mm×D1200mm×H2000mm |
Name | Single phase pure resistance load -R | ||
Model | IMAX3110-30k | IMAX3305-500k | IMAX3305-600k |
Rated Voltage | 3P4W,AC230V/220V/110V | ||
Resistive Power | 33kW | 500kW | 6000kW |
Rated Frequency | 50/60Hz | 50/60Hz | 50/60Hz |
Loading Mode | Step and shift loading | ||
Load Characteristic | Pure Resistance | ||
Load Stepping | The minimum resistance step size is 1kW | ||
Main test items | Power supply detection long - term load, switching device life test | ||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | ||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | ||
Noise | ≤70dB | ≤73dB | ≤75dB |
Air Outlet Mode | Side wind in, side wind out | Wind in from the side down and out from the top. | |
Display Accuracy | 0.1V,0.1A | ||
Control Mode | Local manual control: Local button/air switch/touch screen control | ||
Remote intelligent control: RS485/CAN/ Ethernet | |||
Place of Use | Indoor | ||
Weight | 50kg | 75kg | 150kg |
Size | W600mm×D800mm×H800mm | W600mm×D800mm×H1400mm | W600mm×D800mm×H1600mm |
Name | Three-phase pure resistance load -R | |||||
Model | IMAX3130-50k | IMAX3130-100k | IMAX3130-300k | IMAX3130-500k | IMAX3130-700k | IMAX3130-1000k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V | |||||
Resistive Power | 55kW | 110kW | 310kW | 510kW | 710kW | 1030kW |
Rated Frequency | 50/60Hz | |||||
Loading Mode | Step loading | |||||
Load Characteristic | pure resistance | |||||
Load Stepping | The minimum step size of the resistance divider is 10W | |||||
Main test items | Power supply detection long - term load, switching device life test | |||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | |||||
Noise | ≤75dB | ≤79dB | ≤82dB | |||
Air Outlet Mode | Wind in from the side down and out from the top | Side down ejection/side in side out | Wind in from the side down and out from the top | |||
Display Accuracy | 0.1V,0.1A | |||||
Control Mode | Local manual control: local button/circuit breaker | Local manual control: through the load box 7 inch LCD touch screen. | ||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||||
Place of Use | Indoor | Indoor/Outdoor | ||||
Weight | 80kg | 120kg | 450kg | 650kg | 950kg | 1300kg |
Size | W600mm×D800mm×H1400mm | W600mm×D800mm×H1600mm | sideward :W1500mm×D1300mm×H1400mm ejection:W1200mm*D1200mm*1800mm | sideward :W1750mm×D1300mm×H1400mm | W1200mm×D1400mm×H2000mm | W1800mm×D1200mm×H2000mm |