Flywheel Energy Storage Test Three-phase AC Brake Load Bank

IMAX3200 series AC load bank is AC resistance load bank, the product can cover the power range of 50~6000kVA, the product working voltage range of 0~1140V (AC/DC), the load box can be used alone, or can be used in multiple machines, to meet the needs of higher power use. At the same time can also be customized according to customer requirements to achieve different test functions.

Availability:
Quantity:
  • IMAX2906

  • EMAX

  • 2023105060

Product Introduction

IMAX3000 series AC load boxes are mainly used for performance testing and aging of online high-power UPS (uninterruptible power supplies) and generator sets in power, telecommunications and other departments and manufacturers. It is an important testing and maintenance equipment for the actual load capacity of the equipment. Its application effectively avoids the economic losses of enterprises caused by the failure of backup units or power supply startup, and also provides a scientific basis for the detection of the load capacity of new units and the engineering acceptance of new batteries.

Product Features&Advantage

1. Can meet long-term outdoor use

2. Provide the upper computer operating software

3. RS485, Ethernet, CAN and other communication ports

4. The test steps are programmable, suitable for diesel generator set, gas generator set, anti-reverse power transmission, automatic test

5. Can load any power within the full power range, any power factor, test and display three-phase voltage, current, power, power factor;

6 Power adjustment accuracy: 1kW

7. Use PC data management software to control load loading and load unloading and save test data

Product Parameters

Selection

AC braking resistor cabinet

IMAX2906

Test loop

Type

Pure resistance

Rated voltage

AC1030V-AC100V

Wiring

3P3W

Max power

60kW

Max current

174A

PF

1

Number of circuits

3P3W

Number of incoming circuits

2 in 1 (with 2 external test sources)

Grading

1030V-60kW-17.7Ω;

700V-60kW-8.2Ω;

400V-60kW-2.7Ω;

100V-30kW-0.34Ω。

Accuracy

±3%

Connection

Copper bar

Loop

Voltage

AC220V±10%

Frequency

50Hz

Connection

1P2W

Power

<0.9kW

Power supply mode

External power supply

Display function

Temperature display, voltage and current display, data reading through communication

Loading method

Automatic identification of voltage breaking and automatic loading of load in the braking resistor cabinet

Interface

Ethernet/RS485, Modbu RTU protocol. The specific agreement can be modified as required.

Control mode


1. Emergency stop start control: After pressing the emergency stop button, the device will automatically pull the load based on the current voltage;

2. Fan maintenance button: For daily maintenance, manually start the fan and observe if it is working properly;

3. Short circuit start at dry output point: Short circuit start signal at dry output point. The equipment will automatically load according to the current voltage, and can connect to normally open dry contact signals such as smoke alarm and over temperature alarm;

4. Communication control start stop: By writing a start stop signal through communication, the device will automatically load based on the current voltage, and can monitor the current voltage, current, load gear feedback, device status, and other information of the device;

5. Operation priority, emergency stop button operation>dry contact control>remote communication control.

Connection

Terminal

Box

Way of working

Continuous operation

Insulation level

F

Cooling method

Forced air cooling, front lower and bottom air inlet, top rear air outlet

Noise

≤ 75dB at 1 meter

Protection grade

IP54

Colour

RAL7035

Size

W600mm*D1200mm*H2200mm

Weight

340kg

Move

There are forklift holes at the bottom of the equipment

Protection function

Temperature alarm

The device has a level 2 temperature alarm, where only the buzzer sounds for the level 2 temperature alarm. The buzzer for the level 1 temperature alarm sounds and unloads the load, and outputs a dry node signal to the outside

Smoke temperature alarm

There is a smoke and temperature detector installed on the top of the cabinet, which can provide smoke alarm and output alarm dry node signals to the outside

Short circuit protection

Configure incoming circuit breaker (for live operation)

Fan interlocking

Not starting the fan, unable to load

Fan phase sequence protection

Built in phase sequence conversion switch, the fan can also start in the normal direction when voltage phase sequence error is detected

Fan air volume protection

The device is equipped with a built-in wind pressure switch. When insufficient wind pressure is detected in the fan, the load is stopped and fed back to the upper computer

Low-temperature starting

The control room inside the load cabinet is relatively isolated from the outside, and a heater is installed to meet the starting condition of low temperature -20 ℃

Ground protection

In order to avoid the risk of electric shock caused by the casing being damaged during load operation, the braking resistor cabinet is equipped with a dedicated grounding protection terminal

Voltage withstand test

Withstand voltage characteristics

Resistance to ground: AC3kV, 50Hz, 1 minute, no breakdown, no flying fox

Insulation performance

Insulation characteristics

DC1kV, insulation greater than 10M Ω

Product Applications

1. Marine generator set inspection;
2. Emergency power supply detection;
3. Cable impedance simulation;
4. Switching device life test
5. Inverter and converter testing,
6. Outdoor energy storage test, household energy storage test;
7. Various ATE tests


Specification
Selection

Three phase AC test load bank

IMAX3690

Test

circuit

type

Three-phase AC

voltage

AC400V

50Hz/60Hz

Wiring method

3P4W

frequency

50Hz

maximum power

90KW

PF

0.8

Step accuracy

1kW/0.75kVar

Load accuracy

±3%

Wiring method

Copper bar

control

loop

voltage

AC380V±10%

frequency

50Hz

Wiring

method

3P3W

power

<2.5kW

Power

supply method

External power supply

Display accuracy

Level 0.5

control mode

Remote software control, contactor switching.

communication

interface

RS485

Wiring method

Terminal

Box

Working mode

Continuous operation,7*24H

Insulation level

F

Cooling

method

Forced air cooling, side inlet, side outlet

Protection level

IP23

Color

RAL7035,can be customized according to requirements

size

W1100mm×D1100mm×H1500mm

weight

500kg

Mobile Method

Bottom with casters and top with lifting rings for easy movement

Protection

function

Emergency stop

It can be manually forced to unload with one click, and cannot be loaded in the emergency stop locked state.

temperature

alarm

When the load temperature exceeds the safety threshold, a load alarm will be triggered.

Fan interlocking

protection

The fan has not been turned on, and the load cannot be loaded.

Fan phase sequence

protection

The phase sequence of the fan is connected incorrectly, and the fan can also operate normally.

Grounding

protection

In order to avoid the risk of electric shock caused by the casing being damaged during load operation, the load cabinet is equipped with a dedicated grounding protection terminal.


Previous: 
Next: 
Inquiry

Products

Navigation

Contact us

  +86-769-8831-6780
  +86-15099752515(Mr. Jiang)
    No. 94, Shangzha Road, Houjie Town, Dongguan, Guangdong
Send Us A Message
Copyright @2022 Guangdong Emax Electrical Co., Ltd. All Rights Reserved. Sitemap Support By Leadong Privacy Policy