Availability: | |
---|---|
Quantity: | |
IMAX3510-200KW
EMAX
Number | Project | Technical Indices |
1 | Model | IMAX3510-200k |
2 | Name | AC RLC load bank |
3 | Rated Voltage | AC400V(△-Triangle) AC690V(Y-Star) |
4 | Phase | Three-Phase |
5 | Resistive power | 200kW |
6 | Inductive power | 200kVar |
7 | Capacitive power | 200kVar |
8 | Switching method | Manually switch through external copper bars |
9 | Control method | 1. Three phases can be independently adjustable; 2. Independently adjustable resistive capacitance; 3. Power adjustment can be automatically performed through software |
10 | PF | 1 |
11 | Rated frequency | 50Hz |
12 | Characteristic | RLC load bank |
13 | Step | min 10W, max 50kW |
14 | Protection alarm | Short circuit protection, overcurrent protection, overvoltage protection, fan air volume protection, door limit protection, high temperature fault, emergency stop and other protection functions. |
15 | Measurement and control parameters | Display three-phase voltage, three-phase current, active power, reactive power, apparent power, power factor, frequency and other basic functions |
16 | Adjusting accuracy | 1W/1Var |
17 | Adjusting step size | 10W/10Var |
18 | Chassis Structure | Cabinet type |
19 | mode of transport | With brake casters and handles |
20 | way of working | Continuous operation |
21 | Lighting | There are explosion-proof lighting and power sockets inside the box, signal indicator lights at the back of the box, and alarm lights outside the control room. |
22 | Noise | ≤80dB |
23 | Cooling method | orced air cooling (air enters from the side and exhausts the air); the top faces the rear |
24 | Insulation level | F |
25 | Display Accuracy | 0.5 |
26 | way to control | Touch screen manual control/host computer control: reserved Ethernet/RS485 access to remote system control. |
27 | Weight | 1800kg |
28 | Dimensions | L2500mm× W1500mm× H2200mm |
29 | Load bearing requirements | ≥550kg/m² |
30 | Cabinet color | RAL7035 |
Number | Project | Technical Indices |
1 | Model | IMAX3510-200k |
2 | Name | AC RLC load bank |
3 | Rated Voltage | AC400V(△-Triangle) AC690V(Y-Star) |
4 | Phase | Three-Phase |
5 | Resistive power | 200kW |
6 | Inductive power | 200kVar |
7 | Capacitive power | 200kVar |
8 | Switching method | Manually switch through external copper bars |
9 | Control method | 1. Three phases can be independently adjustable; 2. Independently adjustable resistive capacitance; 3. Power adjustment can be automatically performed through software |
10 | PF | 1 |
11 | Rated frequency | 50Hz |
12 | Characteristic | RLC load bank |
13 | Step | min 10W, max 50kW |
14 | Protection alarm | Short circuit protection, overcurrent protection, overvoltage protection, fan air volume protection, door limit protection, high temperature fault, emergency stop and other protection functions. |
15 | Measurement and control parameters | Display three-phase voltage, three-phase current, active power, reactive power, apparent power, power factor, frequency and other basic functions |
16 | Adjusting accuracy | 1W/1Var |
17 | Adjusting step size | 10W/10Var |
18 | Chassis Structure | Cabinet type |
19 | mode of transport | With brake casters and handles |
20 | way of working | Continuous operation |
21 | Lighting | There are explosion-proof lighting and power sockets inside the box, signal indicator lights at the back of the box, and alarm lights outside the control room. |
22 | Noise | ≤80dB |
23 | Cooling method | orced air cooling (air enters from the side and exhausts the air); the top faces the rear |
24 | Insulation level | F |
25 | Display Accuracy | 0.5 |
26 | way to control | Touch screen manual control/host computer control: reserved Ethernet/RS485 access to remote system control. |
27 | Weight | 1800kg |
28 | Dimensions | L2500mm× W1500mm× H2200mm |
29 | Load bearing requirements | ≥550kg/m² |
30 | Cabinet color | RAL7035 |