600kW RLC Resistive Inductive Capacitive Three-phase 415V Load Bank

A 600kW RLC Load Bank is a versatile electrical testing device designed to simulate real-world load conditions for electrical power systems, including generators, transformers, and UPS systems. It combines resistive, inductive, and capacitive load elements to enable comprehensive testing and performance evaluation under diverse scenarios.
Availability:
Quantity:
  • IMAX3460

  • EMAX

  1. Power Rating: 600kW total capacity, with configurable RLC load settings.

  2. Voltage Rating: Three-phase 415V, compatible with standard industrial and commercial power systems.

  3. Load Adjustability: Independent control of resistive, inductive, and capacitive load elements, allowing precise adjustment of power factor and testing conditions.

  4. Cooling System: Integrated forced-air cooling with temperature monitoring and overheat protection for continuous operation.

  5. Construction:

    • Heavy-duty enclosure with powder-coated steel for durability.

    • IP-rated protection for outdoor/indoor use.

  6. Safety Features:

    • Overload and short-circuit protection.

    • Emergency stop button.

    • Insulated power connections.

  7. Control Options:

    • Local control panel with analog/digital meters for real-time load and power factor monitoring.

    • Remote control capability via communication interfaces (e.g., Ethernet or RS485).

  8. Load Components:

    • Resistive: Pure resistors to simulate active power loads.

    • Inductive: Reactors for reactive power simulation (lagging power factor).

    • Capacitive: Capacitors to simulate leading power factor loads.

Applications:

  • Generator Testing: Ensures reliable operation under various load conditions.

  • Transformer Testing: Evaluates capacity and efficiency under combined RLC loads.

  • UPS Testing: Validates uninterruptible power supply performance.

  • Renewable Energy Systems: Simulates load dynamics for solar and wind power systems.

  • Power Factor Correction: Assess and optimize system power factor with adjustable RLC settings.

Specifications:

  • Rated Voltage: 415V AC, 3-phase, 50/60Hz.

  • Power Steps: Load increments for fine-tuning.

  • Power Factor Range: Adjustable from leading (capacitive) to lagging (inductive).

  • Operating Environment:

    • Temperature: -10°C to +50°C.

    • Humidity: <95% non-condensing.

This load bank is ideal for testing and commissioning power systems in industrial, commercial, and utility settings, providing robust, reliable, and accurate performance simulations.

1. Can conduct anti islanding tests


2. Provide upper computer operation software


3. Equipped with various communication interfaces such as RS485, Ethernet, CAN, etc


4. The test steps can be programmed, which is suitable for Test automation of Solar inverter and energy storage converter


5. It can load any power and any power factor within the full power range, test and display the three-phase voltage, current, power and quality factor of the generating set;


6. Power regulation accuracy: 1W/1Var


7. Control load loading and unloading through PC data management software and save test data


Models&Specifications

Name

Three-phase anti-island Load -RLC

Model

IMAX3510-400k

IMAX3510-600k

IMAX3510-800k

IMAX3510-1000k

IMAX3510-1600k

IMAX3510-2000k

Rated Voltage

3P4W,AC220V/380V/400V/415V/440V

Resistive Power

400kW

600kW

800kW

1000kW

1600kW

2000kW

Inductive power

400kVar

600kVAR

800kVAR

1000kVAR

1600kVAR

2000kVAR

Capacitive Power

400kVar

600kVAR

800kVAR

1000kVAR

1600kVAR

2000kVAR

Rated Frequency

50/60Hz

50/60Hz

50/60Hz

50/60Hz

50/60Hz

50/60Hz

Loading Mode

Resistive capacitance independent adjustable

Load Characteristic

Resistive capacitance integrated load

Load Stepping

The minimum step size of the resistance divider is 10W

The minimum step size of perceptual classification is 10Var

Capacitive divider step size minimum 10Var

Main test items

Grid-connected inverter anti-island effect protection test, inverter efficiency test, power factor test, overload protection test

Protection Alarm

Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions.

Measurement and Control Parameter

Display voltage, current, active power, reactive power, apparent power, quality factor, power factor, frequency and other basic functions.

Noise

≤78dB

≤80dB

≤85dB

Air Outlet Mode

Wind in from the side down and out from the top.

Display Accuracy

0.1V,0.1A

Control Mode

Local manual control: through the load box 7 inch LCD touch screen.

Local manual control: through the load box 10 inch LCD touch screen.

Remote intelligent control: RS485/CAN/ Ethernet

Remote intelligent control: RS485/CAN/ Ethernet

Place of Use

Indoor

Indoor/Outdoor

Weight

3250kg

5450kg

6850kg

7200kg

8500kg

9000kg

Size

W2500mm×D2500mm×H12200mm

W2991mm×D2438mm×H2591mm

10 foot container

W6058mm×D2438mm×H2591mm

20 foot container



Previous: 
Next: 
Inquiry

Products

Navigation

Contact us

  +86-769-8831-6780
  +86-15099752515(Mr. Jiang)
   sales05@emaxgroups.com
    No. 94, Shangzha Road, Houjie Town, Dongguan, Guangdong
Send Us A Message
Copyright @2022 Guangdong Emax Electrical Co., Ltd. All Rights Reserved. Sitemap Support By Leadong Privacy Policy