The RLC Load Bank for Genset Testing is an advanced, reliable, and precise solution designed to ensure the optimal performance and reliability of generator sets (gensets). This state-of-the-art load bank combines resistive, inductive, and capacitive loads to simulate real-world conditions, providing comprehensive testing and validation for genset systems.
Availability: | |
---|---|
Quantity: | |
IMAX3500 Series
EMAX
Product Advantages :
1.Comprehensive Testing Capabilities: The RLC Load Bank offers resistive, inductive, and capacitive loading, allowing for thorough and versatile testing scenarios that closely mimic real-world conditions.
2.High Precision and Accuracy: Advanced control systems and sensors ensure precise load simulation, providing accurate performance data for detailed analysis.
3.Robust and Durable Design: Built with high-quality materials and components, the RLC Load Bank is designed to withstand harsh environments and extended use, ensuring long-term reliability.
4.Safety Features: Integrated safety mechanisms, including overload protection, emergency stop, and fault detection, ensure safe operation and protect both the load bank and the genset being tested.
5.Scalable and Customizable: Available in various configurations and power ratings, the RLC Load Bank can be tailored to meet specific testing requirements and capacities.
6.Portability: Some models offer portable designs, enabling easy transportation and on-site testing, enhancing convenience and flexibility.
The RLC Load Bank for Genset Testing is an indispensable tool for ensuring the reliability, performance, and compliance of gensets across various industries. With its comprehensive testing capabilities, precision, and robust design, it provides unparalleled value and peace of mind for operators and maintenance personnel. Selecting the right model based on specific needs and conditions will maximize the benefits and longevity of both the load bank and the gensets it tests.
Product Advantages :
1.Comprehensive Testing Capabilities: The RLC Load Bank offers resistive, inductive, and capacitive loading, allowing for thorough and versatile testing scenarios that closely mimic real-world conditions.
2.High Precision and Accuracy: Advanced control systems and sensors ensure precise load simulation, providing accurate performance data for detailed analysis.
3.Robust and Durable Design: Built with high-quality materials and components, the RLC Load Bank is designed to withstand harsh environments and extended use, ensuring long-term reliability.
4.Safety Features: Integrated safety mechanisms, including overload protection, emergency stop, and fault detection, ensure safe operation and protect both the load bank and the genset being tested.
5.Scalable and Customizable: Available in various configurations and power ratings, the RLC Load Bank can be tailored to meet specific testing requirements and capacities.
6.Portability: Some models offer portable designs, enabling easy transportation and on-site testing, enhancing convenience and flexibility.
The RLC Load Bank for Genset Testing is an indispensable tool for ensuring the reliability, performance, and compliance of gensets across various industries. With its comprehensive testing capabilities, precision, and robust design, it provides unparalleled value and peace of mind for operators and maintenance personnel. Selecting the right model based on specific needs and conditions will maximize the benefits and longevity of both the load bank and the gensets it tests.
Name | Three-phase anti-island Load -RLC | |||||
Model | IMAX3510-20k | IMAX3510-30k | IMAX3510-60k | IMAX3510-100k | IMAX3510-150k | IMAX3510-200k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V | |||||
Resistive Power | 21kW | 33kW | 63kW | 103kW | 151kW | 200kW |
Inductive power | 21kVar | 33kVAR | 63kVAR | 103kVAR | 151kVAR | 200kVAR |
Capacitive Power | 21kVar | 33kVAR | 63kVAR | 103kVAR | 151kVAR | 200kVAR |
Rated Frequency | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz |
Loading Mode | Resistive capacitance independent adjustable | |||||
Load Characteristic | Resistive capacitance integrated load | |||||
Load Stepping | The minimum step size of the resistance divider is 10W | |||||
The minimum step size of perceptual classification is 10Var | ||||||
Capacitive divider step size minimum 10Var | ||||||
Grid-connected inverter anti-island effect protection test, inverter efficiency test, power factor test, overload protection test | ||||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, quality factor, power factor, frequency and other basic functions. | |||||
Noise | ≤70dB | ≤73dB | ≤75dB | |||
Air Outlet Mode | Wind in from the side down and out from the top. | |||||
Display Accuracy | 0.1V,0.1A | |||||
Control Mode | Local manual control: through the load box 7 inch LCD touch screen. | Local manual control: through the load box 10 inch LCD touch screen. | ||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||||
Place of Use | Indoor | Indoor/Outdoor | ||||
Weight | 250kg | 450kg | 850kg | 1200kg | 1500kg | 2000kg |
Size | W800mm×D1000mm×H1800mm | W1200mm×D1200mm×H1800mm | W1600mm×D1400mm×H2000mm |
Name | Single phase anti-island Load -RLC | ||
Model | IMAX3510-5k | IMAX3510-10k | IMAX3510-20k |
Rated Voltage | 1P2W,AC230V/220V/110V | ||
Resistive Power | 5.1kW | 11.1kW | 21.1kW |
Inductive power | 5.1kVAR | 11.1kVAR | 21.1kVAR |
Capacitive Power | 5.1kVAR | 11.1kVAR | 21.1kVAR |
Rated Frequency | 50/60Hz | 50/60Hz | 50/60Hz |
Loading Mode | 1. Adjustable for three phases respectively; 2. The resistance sensing capacity is independent and adjustable | ||
Load Characteristic | Resistive capacitance integrated load | ||
Load Stepping | The minimum step size of the resistance divider is 10 | ||
The minimum step size of perceptual classification is 10Var | |||
Capacitive divider step size minimum 10Var | |||
Main test items | Grid-connected inverter anti-island effect protection test, inverter efficiency test, power factor test, overload protection test | ||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | ||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, quality factor, power factor, frequency and other basic functions. | ||
Noise | ≤70dB | ≤70dB | ≤75dB |
Air Outlet Mode | Wind in from the side down and out from the top. | Wind in from the side down and out from the top. | Wind in from the side down and out from the top. |
Display Accuracy | 0.1V,0.1A | ||
Control Mode | Local manual control: through the load box 7 inch LCD touch screen. | ||
Remote intelligent control: RS485/CAN/ Ethernet | |||
Place of Use | Indoor | ||
Weight | 80kg | 100kg | 150kg |
Size | W600mm×D800mm×H1200mm | W600mm×D800mm×H1400mm | W600mm×D800mm×H1600mm |
Name | Three-phase anti-island Load -RLC | |||||
Model | IMAX3510-2500k | IMAX3510-3000k | IMAX3510-3600k | IMAX3510-4000k | IMAX3510-5000k | IMAX3510-6000k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V | |||||
Resistive Power | 2500kW | 3000kW | 3600kW | 4000kW | 5000kW | 6000kW |
Inductive power | 2500kVar | 3000kVAR | 3600kVAR | 4000kVAR | 5000kVAR | 6000kVAR |
Capacitive Power | 2500kVar | 3000kVAR | 3600kVAR | 4000kVAR | 5000kVAR | 6000kVAR |
Rated Frequency | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz |
Loading Mode | Resistive capacitance independent adjustable | |||||
Load Characteristic | · Resistive capacitance integrated load | |||||
Load Stepping | The minimum step size of the resistance divider is 10W | |||||
The minimum step size of perceptual classification is 10Var | ||||||
Capacitive divider step size minimum 10Var | ||||||
Main test items | Grid-connected inverter anti-island effect protection test, inverter efficiency test, power factor test, overload protection test | |||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, quality factor, power factor, frequency and other basic functions. | |||||
Noise | ≤78dB | ≤80dB | ≤82dB | |||
Air Outlet Mode | Wind in from the side down and out from the top. | |||||
Display Accuracy | 0.1V,0.1A | |||||
Control Mode | Local manual control: through the load box 10 inch LCD touch screen. | Local manual control: through the load box 10 inch LCD touch screen. | ||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||||
Place of Use | Indoor/Outdoor | Indoor/Outdoor | ||||
Weight | 13000kg | 15000kg | 18500kg | 215000kg | 245000kg | 265000kg |
Size | L9000mm×W2438mm×H2591mm | L9000mm×W2438mm×H2591mm | L12191mm×W2438mm×H2896mm |
Name | Three-phase anti-island Load -RLC | |||||
Model | IMAX3510-400k | IMAX3510-600k | IMAX3510-800k | IMAX3510-1000k | IMAX3510-1600k | IMAX3510-2000k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V | |||||
Resistive Power | 400kW | 600kW | 800kW | 1000kW | 1600kW | 2000kW |
Inductive power | 400kVar | 600kVAR | 800kVAR | 1000kVAR | 1600kVAR | 2000kVAR |
Capacitive Power | 400kVar | 600kVAR | 800kVAR | 1000kVAR | 1600kVAR | 2000kVAR |
Rated Frequency | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz |
Loading Mode | Resistive capacitance independent adjustable | |||||
Load Characteristic | Resistive capacitance integrated load | |||||
Load Stepping | The minimum step size of the resistance divider is 10W | |||||
The minimum step size of perceptual classification is 10Var | ||||||
Capacitive divider step size minimum 10Var | ||||||
Main test items | Grid-connected inverter anti-island effect protection test, inverter efficiency test, power factor test, overload protection test | |||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, quality factor, power factor, frequency and other basic functions. | |||||
Noise | ≤78dB | ≤80dB | ≤82dB | |||
Air Outlet Mode | Wind in from the side down and out from the top. | |||||
Display Accuracy | 0.1V,0.1A | |||||
Control Mode | Local manual control: through the load box 10 inch LCD touch screen. | Local manual control: through the load box 10 inch LCD touch screen. | ||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||||
Place of Use | Indoor/Outdoor | Indoor/Outdoor | ||||
Weight | 3250kg | 5450kg | 6850kg | 7200kg | 8500kg | 9000kg |
Size | W2500mm×D2500mm×H2200mm | W2991mm×D2438mm×H2591mm | W6058mm×D2438mm×H2591mm |
Name | Three-phase anti-island Load -RLC | |||||
Model | IMAX3510-20k | IMAX3510-30k | IMAX3510-60k | IMAX3510-100k | IMAX3510-150k | IMAX3510-200k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V | |||||
Resistive Power | 21kW | 33kW | 63kW | 103kW | 151kW | 200kW |
Inductive power | 21kVar | 33kVAR | 63kVAR | 103kVAR | 151kVAR | 200kVAR |
Capacitive Power | 21kVar | 33kVAR | 63kVAR | 103kVAR | 151kVAR | 200kVAR |
Rated Frequency | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz |
Loading Mode | Resistive capacitance independent adjustable | |||||
Load Characteristic | Resistive capacitance integrated load | |||||
Load Stepping | The minimum step size of the resistance divider is 10W | |||||
The minimum step size of perceptual classification is 10Var | ||||||
Capacitive divider step size minimum 10Var | ||||||
Grid-connected inverter anti-island effect protection test, inverter efficiency test, power factor test, overload protection test | ||||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, quality factor, power factor, frequency and other basic functions. | |||||
Noise | ≤70dB | ≤73dB | ≤75dB | |||
Air Outlet Mode | Wind in from the side down and out from the top. | |||||
Display Accuracy | 0.1V,0.1A | |||||
Control Mode | Local manual control: through the load box 7 inch LCD touch screen. | Local manual control: through the load box 10 inch LCD touch screen. | ||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||||
Place of Use | Indoor | Indoor/Outdoor | ||||
Weight | 250kg | 450kg | 850kg | 1200kg | 1500kg | 2000kg |
Size | W800mm×D1000mm×H1800mm | W1200mm×D1200mm×H1800mm | W1600mm×D1400mm×H2000mm |
Name | Single phase anti-island Load -RLC | ||
Model | IMAX3510-5k | IMAX3510-10k | IMAX3510-20k |
Rated Voltage | 1P2W,AC230V/220V/110V | ||
Resistive Power | 5.1kW | 11.1kW | 21.1kW |
Inductive power | 5.1kVAR | 11.1kVAR | 21.1kVAR |
Capacitive Power | 5.1kVAR | 11.1kVAR | 21.1kVAR |
Rated Frequency | 50/60Hz | 50/60Hz | 50/60Hz |
Loading Mode | 1. Adjustable for three phases respectively; 2. The resistance sensing capacity is independent and adjustable | ||
Load Characteristic | Resistive capacitance integrated load | ||
Load Stepping | The minimum step size of the resistance divider is 10 | ||
The minimum step size of perceptual classification is 10Var | |||
Capacitive divider step size minimum 10Var | |||
Main test items | Grid-connected inverter anti-island effect protection test, inverter efficiency test, power factor test, overload protection test | ||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | ||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, quality factor, power factor, frequency and other basic functions. | ||
Noise | ≤70dB | ≤70dB | ≤75dB |
Air Outlet Mode | Wind in from the side down and out from the top. | Wind in from the side down and out from the top. | Wind in from the side down and out from the top. |
Display Accuracy | 0.1V,0.1A | ||
Control Mode | Local manual control: through the load box 7 inch LCD touch screen. | ||
Remote intelligent control: RS485/CAN/ Ethernet | |||
Place of Use | Indoor | ||
Weight | 80kg | 100kg | 150kg |
Size | W600mm×D800mm×H1200mm | W600mm×D800mm×H1400mm | W600mm×D800mm×H1600mm |
Name | Three-phase anti-island Load -RLC | |||||
Model | IMAX3510-2500k | IMAX3510-3000k | IMAX3510-3600k | IMAX3510-4000k | IMAX3510-5000k | IMAX3510-6000k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V | |||||
Resistive Power | 2500kW | 3000kW | 3600kW | 4000kW | 5000kW | 6000kW |
Inductive power | 2500kVar | 3000kVAR | 3600kVAR | 4000kVAR | 5000kVAR | 6000kVAR |
Capacitive Power | 2500kVar | 3000kVAR | 3600kVAR | 4000kVAR | 5000kVAR | 6000kVAR |
Rated Frequency | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz |
Loading Mode | Resistive capacitance independent adjustable | |||||
Load Characteristic | · Resistive capacitance integrated load | |||||
Load Stepping | The minimum step size of the resistance divider is 10W | |||||
The minimum step size of perceptual classification is 10Var | ||||||
Capacitive divider step size minimum 10Var | ||||||
Main test items | Grid-connected inverter anti-island effect protection test, inverter efficiency test, power factor test, overload protection test | |||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, quality factor, power factor, frequency and other basic functions. | |||||
Noise | ≤78dB | ≤80dB | ≤82dB | |||
Air Outlet Mode | Wind in from the side down and out from the top. | |||||
Display Accuracy | 0.1V,0.1A | |||||
Control Mode | Local manual control: through the load box 10 inch LCD touch screen. | Local manual control: through the load box 10 inch LCD touch screen. | ||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||||
Place of Use | Indoor/Outdoor | Indoor/Outdoor | ||||
Weight | 13000kg | 15000kg | 18500kg | 215000kg | 245000kg | 265000kg |
Size | L9000mm×W2438mm×H2591mm | L9000mm×W2438mm×H2591mm | L12191mm×W2438mm×H2896mm |
Name | Three-phase anti-island Load -RLC | |||||
Model | IMAX3510-400k | IMAX3510-600k | IMAX3510-800k | IMAX3510-1000k | IMAX3510-1600k | IMAX3510-2000k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V | |||||
Resistive Power | 400kW | 600kW | 800kW | 1000kW | 1600kW | 2000kW |
Inductive power | 400kVar | 600kVAR | 800kVAR | 1000kVAR | 1600kVAR | 2000kVAR |
Capacitive Power | 400kVar | 600kVAR | 800kVAR | 1000kVAR | 1600kVAR | 2000kVAR |
Rated Frequency | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz |
Loading Mode | Resistive capacitance independent adjustable | |||||
Load Characteristic | Resistive capacitance integrated load | |||||
Load Stepping | The minimum step size of the resistance divider is 10W | |||||
The minimum step size of perceptual classification is 10Var | ||||||
Capacitive divider step size minimum 10Var | ||||||
Main test items | Grid-connected inverter anti-island effect protection test, inverter efficiency test, power factor test, overload protection test | |||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, quality factor, power factor, frequency and other basic functions. | |||||
Noise | ≤78dB | ≤80dB | ≤82dB | |||
Air Outlet Mode | Wind in from the side down and out from the top. | |||||
Display Accuracy | 0.1V,0.1A | |||||
Control Mode | Local manual control: through the load box 10 inch LCD touch screen. | Local manual control: through the load box 10 inch LCD touch screen. | ||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||||
Place of Use | Indoor/Outdoor | Indoor/Outdoor | ||||
Weight | 3250kg | 5450kg | 6850kg | 7200kg | 8500kg | 9000kg |
Size | W2500mm×D2500mm×H2200mm | W2991mm×D2438mm×H2591mm | W6058mm×D2438mm×H2591mm |