Home / Products / RLC Load Bank / R/RL/RC/ RLC Load Bank for Genset Testing

Product Category

PRODUCT DETAIL

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

R/RL/RC/ RLC Load Bank for Genset Testing

The RLC Load Bank for Genset Testing is an advanced, reliable, and precise solution designed to ensure the optimal performance and reliability of generator sets (gensets). This state-of-the-art load bank combines resistive, inductive, and capacitive loads to simulate real-world conditions, providing comprehensive testing and validation for genset systems.

Availability:
Quantity:
  • IMAX3500 Series

  • EMAX

Product Advantages :


1.Comprehensive Testing Capabilities: The RLC Load Bank offers resistive, inductive, and capacitive loading, allowing for thorough and versatile testing scenarios that closely mimic real-world conditions.


2.High Precision and Accuracy: Advanced control systems and sensors ensure precise load simulation, providing accurate performance data for detailed analysis.


3.Robust and Durable Design: Built with high-quality materials and components, the RLC Load Bank is designed to withstand harsh environments and extended use, ensuring long-term reliability.


4.Safety Features: Integrated safety mechanisms, including overload protection, emergency stop, and fault detection, ensure safe operation and protect both the load bank and the genset being tested.


5.Scalable and Customizable: Available in various configurations and power ratings, the RLC Load Bank can be tailored to meet specific testing requirements and capacities.


6.Portability: Some models offer portable designs, enabling easy transportation and on-site testing, enhancing convenience and flexibility.

 

The RLC Load Bank for Genset Testing is an indispensable tool for ensuring the reliability, performance, and compliance of gensets across various industries. With its comprehensive testing capabilities, precision, and robust design, it provides unparalleled value and peace of mind for operators and maintenance personnel. Selecting the right model based on specific needs and conditions will maximize the benefits and longevity of both the load bank and the gensets it tests.

Models&Specifications

Name

Three-phase anti-island Load -RLC

Model

IMAX3510-20k

IMAX3510-30k

IMAX3510-60k

IMAX3510-100k

IMAX3510-150k

IMAX3510-200k

Rated Voltage

3P4WAC220V/380V/400V/415V/440V

Resistive Power

21kW

33kW

63kW

103kW

151kW

200kW

Inductive power

21kVar

33kVAR

63kVAR

103kVAR

151kVAR

200kVAR

Capacitive Power

21kVar

33kVAR

63kVAR

103kVAR

151kVAR

200kVAR

Rated Frequency

50/60Hz

50/60Hz

50/60Hz

50/60Hz

50/60Hz

50/60Hz

Loading Mode

Resistive capacitance independent adjustable

Load Characteristic

Resistive capacitance integrated load

Load Stepping

The minimum step size of the resistance divider is 10W

The minimum step size of perceptual classification is 10Var

Capacitive divider step size minimum 10Var

Main test items

Grid-connected inverter anti-island effect protection test, inverter efficiency test, power factor test, overload protection test

Protection Alarm

Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions.

Measurement and Control Parameter

Display voltage, current, active power, reactive power, apparent power, quality factor, power factor, frequency and other basic functions.

Noise

≤70dB

≤73dB

≤75dB

Air Outlet Mode

Wind in from the side down and out from the top.

Display Accuracy

0.1V0.1A

Control Mode

Local manual control: through the load box 7 inch LCD touch screen.

Local manual control: through the load box 10 inch LCD touch screen.

Remote intelligent control: RS485/CAN/ Ethernet

Remote intelligent control: RS485/CAN/ Ethernet

Place of Use

Indoor

Indoor/Outdoor

Weight

250kg

450kg

850kg

1200kg

1500kg

2000kg

Size

W800mm×D1000mm×H1800mm

W1200mm×D1200mm×H1800mm

W1600mm×D1400mm×H2000mm

 


 

Name

Single phase anti-island Load -RLC

Model

IMAX3510-5k

IMAX3510-10k

IMAX3510-20k

Rated Voltage

1P2WAC230V/220V/110V

Resistive Power

5.1kW

11.1kW

21.1kW

Inductive power

5.1kVAR

11.1kVAR

21.1kVAR

Capacitive Power

5.1kVAR

11.1kVAR

21.1kVAR

Rated Frequency

50/60Hz

50/60Hz

50/60Hz

Loading Mode

1. Adjustable for three phases respectively; 2. The resistance sensing capacity is independent and adjustable

Load Characteristic

Resistive capacitance integrated load

Load Stepping

The minimum step size of the resistance divider is 10

The minimum step size of perceptual classification is 10Var

Capacitive divider step size minimum 10Var

Main test items

Grid-connected inverter anti-island effect protection test, inverter efficiency test, power factor test, overload protection test

Protection Alarm

Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions.

Measurement and Control Parameter

Display voltage, current, active power, reactive power, apparent power, quality factor, power factor, frequency and other basic functions.

Noise

≤70dB

≤70dB

≤75dB

Air Outlet Mode

Wind in from the side down and out from the top.

Wind in from the side down and out from the top.

Wind in from the side down and out from the top.

Display Accuracy

0.1V0.1A

Control Mode

Local manual control: through the load box 7 inch LCD touch screen.

Remote intelligent control: RS485/CAN/ Ethernet

Place of Use

Indoor

Weight

80kg

100kg

150kg

Size

W600mm×D800mm×H1200mm

W600mm×D800mm×H1400mm

W600mm×D800mm×H1600mm

 

Name

Three-phase anti-island Load -RLC

Model

IMAX3510-2500k

IMAX3510-3000k

IMAX3510-3600k

IMAX3510-4000k

IMAX3510-5000k

IMAX3510-6000k

Rated Voltage

3P4WAC220V/380V/400V/415V/440V

Resistive Power

2500kW

3000kW

3600kW

4000kW

5000kW

6000kW

Inductive power

2500kVar

3000kVAR

3600kVAR

4000kVAR

5000kVAR

6000kVAR

Capacitive Power

2500kVar

3000kVAR

3600kVAR

4000kVAR

5000kVAR

6000kVAR

Rated Frequency

50/60Hz

50/60Hz

50/60Hz

50/60Hz

50/60Hz

50/60Hz

Loading Mode

Resistive capacitance independent adjustable

Load Characteristic

· 

Resistive capacitance integrated load

Load Stepping

The minimum step size of the resistance divider is 10W

The minimum step size of perceptual classification is 10Var

Capacitive divider step size minimum 10Var

Main test items

Grid-connected inverter anti-island effect protection test, inverter efficiency test, power factor test, overload protection test

Protection Alarm

Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions.

Measurement and Control Parameter

Display voltage, current, active power, reactive power, apparent power, quality factor, power factor, frequency and other basic functions.

Noise

≤78dB

≤80dB

≤82dB

Air Outlet Mode

Wind in from the side down and out from the top.

Display Accuracy

0.1V0.1A

Control Mode

Local manual control: through the load box 10 inch LCD touch screen.

Local manual control: through the load box 10 inch LCD touch screen.

Remote intelligent control: RS485/CAN/ Ethernet

Remote intelligent control: RS485/CAN/ Ethernet

Place of Use

Indoor/Outdoor

Indoor/Outdoor

Weight

13000kg

15000kg

18500kg

215000kg

245000kg

265000kg

Size

L9000mm×W2438mm×H2591mm
9m Container

L9000mm×W2438mm×H2591mm
40-Foot Container

L12191mm×W2438mm×H2896mm
40HQ Container


 

Name

Three-phase anti-island Load -RLC

Model

IMAX3510-400k

IMAX3510-600k

IMAX3510-800k

IMAX3510-1000k

IMAX3510-1600k

IMAX3510-2000k

Rated Voltage

3P4W,AC220V/380V/400V/415V/440V

Resistive Power

400kW

600kW

800kW

1000kW

1600kW

2000kW

Inductive power

400kVar

600kVAR

800kVAR

1000kVAR

1600kVAR

2000kVAR

Capacitive Power

400kVar

600kVAR

800kVAR

1000kVAR

1600kVAR

2000kVAR

Rated Frequency

50/60Hz

50/60Hz

50/60Hz

50/60Hz

50/60Hz

50/60Hz

Loading Mode

Resistive capacitance independent adjustable

Load Characteristic

Resistive capacitance integrated load

Load Stepping

The minimum step size of the resistance divider is 10W

The minimum step size of perceptual classification is 10Var

Capacitive divider step size minimum 10Var

Main test items

Grid-connected inverter anti-island effect protection test, inverter efficiency test, power factor test, overload protection test

Protection Alarm

Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions.

Measurement and Control Parameter

Display voltage, current, active power, reactive power, apparent power, quality factor, power factor, frequency and other basic functions.

Noise

≤78dB

≤80dB

≤82dB

Air Outlet Mode

Wind in from the side down and out from the top.

Display Accuracy

0.1V,0.1A

Control Mode

Local manual control: through the load box 10 inch LCD touch screen.

Local manual control: through the load box 10 inch LCD touch screen.

Remote intelligent control: RS485/CAN/ Ethernet

Remote intelligent control: RS485/CAN/ Ethernet

Place of Use

Indoor/Outdoor

Indoor/Outdoor

Weight

3250kg

5450kg

6850kg

7200kg

8500kg

9000kg

Size

W2500mm×D2500mm×H2200mm

W2991mm×D2438mm×H2591mm
10-Foot Container

W6058mm×D2438mm×H2591mm
20-Foot Container


Previous: 
Next: 
Inquiry

Products

Navigation

Contact us

  +86-769-8831-6780
  +86-15099752515(Mr. Jiang)
   sales05@emaxgroups.com
    No. 94, Shangzha Road, Houjie Town, Dongguan, Guangdong
Send Us A Message
Copyright @2022 Guangdong Emax Electrical Co., Ltd. All Rights Reserved. Sitemap Support By Leadong Privacy Policy