Home / Products / AC Load Bank / DC50V Low Power Relay Life Test Resistive Load Bank

Product Category

PRODUCT DETAIL

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

DC50V Low Power Relay Life Test Resistive Load Bank

The DC50V contact load current status indicator light corresponds to the working status of 12 dynamic and static closing circuits, which is on when working and off when not working.
The main switch of the load power supply supplies power to the load, and the coil power supplies power to the relay coil. The instrument displays real-time voltage and current parameters of the load and coil.
The touch screen is used to input or modify test parameters, control the start or stop of testing.
The main power switch starts the equipment, and after pressing the test start button, the indicator light for closing and releasing according to the working status lights up and off.
The alarm is a buzzer that sounds when there is an abnormality in the device.
The emergency stop is an emergency stop button, which will cause the equipment to alarm and stop testing after being pressed.
Availability:
Quantity:
  • IMAX-II

  • EMAX

1. The load cabinet is mainly designed for each different voltage and current load requirement proposed by the user, providing output wiring ports for convenient product connection, and displaying the connection status of each load with LED on the panel.


2. The load cabinet can be used for life testing of single coil monostable electromagnetic relays, double coil double pulse, and single coil double pulse magnetic retention relays.


3. The load cabinet is equipped with a built-in oscillator, which uses a single chip microcomputer as the main control. The working parameters are set in the Chinese menu, and the display is applied on a LCD screen. Parameter setting requirements: the maximum number of times can be set to 99999999, and the on and off time can be set within the range of 0.01s to 100h (160h is the best, with an accuracy of ≤ 2%).


4. Relay coil voltage: 0-60Vdc/15A/900W, at least 4 wire package interfaces are required. (Accuracy ≤ 2%, ripple amplitude ≤ 100mV (effective value)). When the working voltage is turned on and off, it is a vertical square wave (the rising edge is required to be ≤ 0.2ms, and the falling edge is required to be ≤ 0.2ms). Control with electronic switches.


5. Dual coil dual pulse output width range: 5ms~999ms (step value 1ms, accuracy ± 5%).


6. The load cabinet is equipped with LED indicator, resistance output terminal, Computer fan, enclosure grounding fuse (8) and other necessary equipment.


7. The device is equipped with a load power supply of 0-60V/120A/7.5KW (accuracy ≤ 2%, ripple amplitude ≤ 100mV (effective value), and load stability rate ≤ 0.5%).


7.1 Output load type: 50Vd. c., 0.25A/0.5A/1A/5A, 12 channel conversion (12 sets of contacts for each load, including 12 dynamic and 12 static contacts, totaling 24 load points). During the test, one load current can be selected for testing, or multiple load current combinations can be used for testing (such as stacking 1A, 5A, 0.5A, and each channel can output 50V/6.5A).


7.2 Test load conditions: The transfer contact of the tested relay must be connected to the positive pole of the load power supply, and each contact for dynamic and static closing must be connected to a separate load to the negative pole of the load power supply. The transfer terminal is the positive pole of the load power supply.


The accuracy of the load current at each point is required to reach ± 5%. It must comply with relevant standards, and the installation of load resistors must be conducive to heat dissipation. Resistors must not interfere with each other.


9. The load cabinet can monitor the relay contacts with lights, that is, each load channel corresponds to one monitoring light. Simultaneously equipped with suction and release status indicator lights. The output interface mode is terminal blocks, which can withstand the specified load current, including 12 dynamic closing terminal blocks, 12 static closing terminal blocks, and 12 conversion terminal blocks. Clear identification should be provided, and the terminal blocks should correspond to the corresponding indicator lights.


10. The operation panel of the equipment should be equipped with at least 8 shell grounding fuse holders and reserved with grounding terminal terminals.


11. Maximum cabinet volume: 2000 mm (H) × 1200 mm (W) × 900 mm (D), weight ≤ 500Kg, and the load cabinet is equipped with a solid and sturdy roller device, making it easy to move.


12. The input power supply is AC 220V ± 20% (50Hz).


13. The equipment uses electrostatic protective materials, which comply with Q/QJA 120-2013 "Testing Requirements for Antistatic Systems of Aerospace Electronic Products". The absolute static voltage of the equipment is less than 200V


14. Noise ≤ 75dB.


Previous: 
Next: 
Inquiry

Products

Navigation

Contact us

  +86-769-8831-6780
  +86-15099752515(Mr. Jiang)
    No. 94, Shangzha Road, Houjie Town, Dongguan, Guangdong
Send Us A Message
Copyright @2022 Guangdong Emax Electrical Co., Ltd. All Rights Reserved. Sitemap Support By Leadong Privacy Policy