IMAX 3200 Series AC load bank is an AC resistive load bank, which is the ultimate solution for testing and verifying power system performance. Designed to simulate real conditions, this load bank provides accurate and reliable resistive load testing for generators, UPS systems and other critical equipment. With its robust structure and user-friendly interface, it ensures accurate results and easy operation
Product Features&Advantage
1. Can meet long-term outdoor use;
2. Provide the upper computer operating software
3. RS485, Ethernet, CAN and other communication ports
4. The test steps are programmable, suitable for diesel generator set, gas generator set, anti-reverse power transmission, automatic test
5. Can load any power within the full power range, any power factor, test and display three-phase voltage, current, power, power factor;
6 Power adjustment accuracy: 1kW
7. Use PC data management software to control load loading and load unloading and save test data
Name | Single phase resistive load -RL | ||
Model | IMAX3210-25k | IMAX3210-50k | IMAX3210-100k |
Rated Voltage | 1P2W,AC230V/220V/110V | ||
Resistive Power | 20kW | 40kW | 80kW |
Inductive power | 15kVar | 30kVar | 75kVar |
Rated Frequency | 50/60Hz | 50/60Hz | 50/60Hz |
Loading Mode | Step and shift loading | ||
Load Characteristic | Integrated resistance | ||
Load Stepping | The minimum resistance step size is 0.1kW/0.1kVar | ||
Main test items | Power supply detection long - term load, switching device life test | ||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | ||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | ||
Noise | ≤70dB | ≤73dB | ≤75dB |
Air Outlet Mode | · Side wind in, side wind out
| · Wind in from the side down and out from the top
| |
Display Accuracy | 0.1V,0.1A | ||
Control Mode | Local manual control: Local button/air switch/touch screen control | ||
Remote intelligent control: RS485/CAN/ Ethernet | |||
Place of Use | Indoor | ||
Weight | 120kg | 220kg | 350kg |
Size | W600mm×D800mm×H800mm | W800mm×D800mm×H1400mm | W800mm×D800mm×H1600mm |
Name | Three-phase resistive load -RL | |||||
Model | IMAX3230-125k | IMAX3230-250k | IMAX3230-500k | IMAX3230-625k | IMAX3230-750k | IMAX3230-1000k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V | |||||
Resistive Power | 100kW | 200kW | 400kW | 500kW | 600kW | 800kW |
Inductive power | 75kVar | 150kVar | 300kVar | 375kVar | 450kVar | 600kVar |
Rated Frequency | 50/60Hz | |||||
Loading Mode | Step loading | |||||
Load Characteristic | Integrated resistance | |||||
Load Stepping | The minimum resistance step length is 1kW/1kVar | |||||
Main test items | Power supply detection long - term load, switching device life test | |||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | |||||
Noise | ≤75dB | ≤80dB | ≤85dB | |||
Air Outlet Mode | Wind in from the side down and out from the top. | Side down ejection/side in side out | Wind in from the side down and out from the top. | |||
Display Accuracy | 0.1V,0.1A | |||||
Control Mode | Local manual control: Local button/air switch | Local manual control: through the load box 7 inch LCD touch screen. | ||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||||
Place of Use | Indoor | Indoor/Outdoor | ||||
Weight | 350kg | 650kg | 1100kg | 1350kg | 1650kg | 2300kg |
Size | W800mm×D800mm×H1600mm | W1000mm×D1200mm×H1600mm | W1200mm*D1400mm*1800mm |
| W1800mm×D1600mm×H2000mm | W2000mm×D1800mm×H2000mm |