Resistive-reactive load banks: To test at conditions replicating a lagging power factor and to ensure complete engine and alternator test a resistive-reactive load bank is essential.
1. Can meet long-term outdoor use;
2. Provide the upper computer operating software
3. RS485, Ethernet, CAN and other communication ports
4. The test steps are programmable, suitable for diesel generator set, gas generator set, anti-reverse power transmission, automatic test
5. Can load any power within the full power range, any power factor, test and display three-phase voltage, current, power, power factor;
6 Power adjustment accuracy: 1kW
7. Use PC data management software to control load loading and load unloading and save test data
Reactive (Inductive) only load banks available
Typical power factor 0.8
Voltage up to 690V
50 – 60 HZ
50kVA to 6250kVA
IP55 standard protection
Standard canopy sizes to 300kVA
Container packages for 375kVA and above
Multiple 1kVA load steps
Stainless steel finned elements
Choice of control system for all units – suited to application & operators
1. Marine generator set inspection;
2. Emergency power supply detection;
3. Cable impedance simulation;
4. Switching device life test
5. Inverter and converter testing,
6. Outdoor energy storage test, household energy storage test;
7. Various ATE tests
Specification
Selection | Three phase AC test load bank | |
IMAX3690 | ||
Test circuit | type | Three-phase AC |
voltage | AC400V 50Hz/60Hz | |
Wiring method | 3P4W | |
frequency | 50Hz | |
maximum power | 90KW | |
PF | 0.8 | |
Step accuracy | 1kW/0.75kVar | |
Load accuracy | ±3% | |
Wiring method | Copper bar | |
control loop | voltage | AC380V±10% |
frequency | 50Hz | |
Wiring method | 3P3W | |
power | <2.5kW | |
Power supply method | External power supply | |
Display accuracy | Level 0.5 | |
control mode | Remote software control, contactor switching. | |
communication interface | RS485 | |
Wiring method | Terminal | |
Box | Working mode | Continuous operation,7*24H |
Insulation level | F | |
Cooling method | Forced air cooling, side inlet, side outlet | |
Protection level | IP23 | |
Color | RAL7035,can be customized according to requirements | |
size | W1100mm×D1100mm×H1500mm | |
weight | 500kg | |
Mobile Method | Bottom with casters and top with lifting rings for easy movement | |
Protection function | Emergency stop | It can be manually forced to unload with one click, and cannot be loaded in the emergency stop locked state. |
temperature alarm | When the load temperature exceeds the safety threshold, a load alarm will be triggered. | |
Fan interlocking protection | The fan has not been turned on, and the load cannot be loaded. | |
Fan phase sequence protection | The phase sequence of the fan is connected incorrectly, and the fan can also operate normally. | |
Grounding protection | In order to avoid the risk of electric shock caused by the casing being damaged during load operation, the load cabinet is equipped with a dedicated grounding protection terminal. |