Availability: | |
---|---|
Quantity: | |
The containerized resistive load bank features a user-friendly control interface, allowing operators to easily set and monitor load levels, track performance metrics, and conduct tests in a safe and controlled environment. With power ratings ranging from 500 kW to 6 MW, this versatile unit is suitable for a wide range of applications, from routine maintenance to factory acceptance testing. The containerized design enables easy transportation, deployment, and storage, making it ideal for both on-site and off-site testing scenarios.
High Precision and Reliability:
Provides accurate and stable load testing to ensure the reliability and efficiency of power systems.
Helps identify potential issues before they cause critical failures.
Portability and Flexibility:
Housed in a durable, weather-resistant container, the load bank is easily transportable, allowing for quick deployment at various locations.
Suitable for a wide range of testing applications, from small-scale maintenance checks to large-scale performance evaluations.
User-Friendly Interface:
Equipped with an intuitive control system for easy operation and monitoring.
Allows operators to conduct tests with minimal setup time and effort.
Safety and Compliance:
Designed with multiple safety features, including emergency stop buttons, over-temperature protection, and fault indicators.
Complies with international standards for safety and performance, ensuring secure and dependable operation.
Cost-Effective Maintenance:
Enables proactive maintenance by simulating real-world load conditions, reducing the risk of unexpected downtime and costly repairs.
Extends the life of power systems by ensuring they are always tested under optimal conditions.
Scalability:
Available in various power ratings to meet specific testing requirements.
Can be integrated with additional load banks for larger systems, providing scalability as your testing needs grow.
The containerized resistive load bank features a user-friendly control interface, allowing operators to easily set and monitor load levels, track performance metrics, and conduct tests in a safe and controlled environment. With power ratings ranging from 500 kW to 6 MW, this versatile unit is suitable for a wide range of applications, from routine maintenance to factory acceptance testing. The containerized design enables easy transportation, deployment, and storage, making it ideal for both on-site and off-site testing scenarios.
High Precision and Reliability:
Provides accurate and stable load testing to ensure the reliability and efficiency of power systems.
Helps identify potential issues before they cause critical failures.
Portability and Flexibility:
Housed in a durable, weather-resistant container, the load bank is easily transportable, allowing for quick deployment at various locations.
Suitable for a wide range of testing applications, from small-scale maintenance checks to large-scale performance evaluations.
User-Friendly Interface:
Equipped with an intuitive control system for easy operation and monitoring.
Allows operators to conduct tests with minimal setup time and effort.
Safety and Compliance:
Designed with multiple safety features, including emergency stop buttons, over-temperature protection, and fault indicators.
Complies with international standards for safety and performance, ensuring secure and dependable operation.
Cost-Effective Maintenance:
Enables proactive maintenance by simulating real-world load conditions, reducing the risk of unexpected downtime and costly repairs.
Extends the life of power systems by ensuring they are always tested under optimal conditions.
Scalability:
Available in various power ratings to meet specific testing requirements.
Can be integrated with additional load banks for larger systems, providing scalability as your testing needs grow.
Name | Container medium voltage pure resistance load -R | ||||||||
Model | IMAX4510-1000k | IMAX4510-2000k | IMAX4510-2500k | IMAX4510-3000k | IMAX4510-4000k | IMAX4510-5000k | |||
Rated Voltage | 3P4W,AC6.3kV/6.6kV/10kV/11kV/13.8kV | ||||||||
Resistive Power | 1000kW | 2000kW | 2500kW | 3000kW | 4000kW | 5000kW | |||
Rated Frequency | 50/60Hz | ||||||||
Loading Mode | Step loading | ||||||||
power factor | 1 | ||||||||
Load Stepping | The minimum step size of the resistance divider is 10kW | ||||||||
Main test items | Power supply detection long - term load, switching device life test | ||||||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, wind pressure protection, emergency stop and other protection functions | ||||||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | ||||||||
Noise | ≤85dB | ≤86dB | ≤88dB | ||||||
Air Outlet Mode | Wind in from the side down and out from the top. | ||||||||
Display Accuracy | 0.1V,0.1A | ||||||||
Control Mode | Local manual control: through the load bank 7 inch LCD touch screen. | ||||||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | ||||||||
Place of Use | Indoor | Indoor/Outdoor | |||||||
Weight | 3500kg | 4200kg | 6500kg | 7500kg | 9200kg | 11500kg | |||
Size | L2991mm×W2438mm×H2896mm | L6058mm×W2438mm×H2896mm | L7500mm×W2438mm×H2896mm | L9000mm×W2438mm×H2896mm | L12192mm×W2438mm×H2896mm |
Name | Container medium voltage resistance inductive load -RL | |||
Model | IMAX4130-1500k | IMAX4130-2000k | IMAX4130-3000k | IMAX4130-4000k |
Rated Voltage | 3P4W,AC6.3kV/6.6kV/10kV/11kV/13.8kV | |||
Resistive Power | 1200kW | 1600kW | 2400kW | 3200kW |
Inductive power | 900kVar | 1200kVar | 1800kVar | 2400kVar |
Rated Frequency | 50/60Hz | |||
Loading Mode | Step loading | |||
power factor | 0.8-1 | |||
Load Stepping | The minimum dividing step is 10kW/7.5kVar | |||
Main test items | Generator set testing | |||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, wind pressure protection, emergency stop and other protection functions | |||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | |||
Noise | ≤85dB | ≤86dB | ||
Air Outlet Mode | Wind in from the side down and out from the top. | |||
Display Accuracy | 0.1V,0.1A | |||
Control Mode | Local manual control: through the load bank 7 inch LCD touch screen. | |||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||
Place of Use | Indoor | Indoor/Outdoor | ||
Weight | 9500kg | 14000kg | 16500kg | 19000kg |
Size | L4500mm×W2438mm×H2896mm | L9000mm×W2438mm×H2896mm 9m container | L12192mm×W2438mm×H2896mm |
Name |
Pressure resistance capacity load in container -RC
| ||||
Model | IMAX4130-1500k | IMAX4130-2000k | IMAX4130-3000k | IMAX4130-4000k | |
Rated Voltage | 3P4W,AC6.3kV/6.6kV/10kV/11kV/13.8kV | ||||
Resistive Power | 1200kW | 1600kW | 2400kW | 3200kW | |
Inductive power | 900kVar | 1200kVar | 1800kVar | 2400kVar | |
Rated Frequency | 50/60Hz | ||||
Loading Mode | Step loading | ||||
power factor | 0.8-1 | ||||
Load Stepping | The minimum dividing step is 10kW/7.5kVar | ||||
Main test items | Generator set testing | ||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, wind pressure protection, emergency stop and other protection functions | ||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | ||||
Noise | ≤85dB | ≤86dB | |||
Air Outlet Mode | Wind in from the side down and out from the top | ||||
Display Accuracy | 0.1V,0.1A | ||||
Control Mode | Local manual control: through the load bank 7 inch LCD touch screen. | ||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | ||||
Place of Use | Indoor | Indoor/Outdoor | |||
Weight | 9500kg | 14000kg | 16500kg | 19000kg | |
Size | L4500mm×W2438mm×H2896mm 4.5m container | L9000mm×W2438mm×H2896mm 9m container | L12192mm×W2438mm×H2896mm |
Name | Container medium voltage pure resistance load -R | ||||||||
Model | IMAX4510-1000k | IMAX4510-2000k | IMAX4510-2500k | IMAX4510-3000k | IMAX4510-4000k | IMAX4510-5000k | |||
Rated Voltage | 3P4W,AC6.3kV/6.6kV/10kV/11kV/13.8kV | ||||||||
Resistive Power | 1000kW | 2000kW | 2500kW | 3000kW | 4000kW | 5000kW | |||
Rated Frequency | 50/60Hz | ||||||||
Loading Mode | Step loading | ||||||||
power factor | 1 | ||||||||
Load Stepping | The minimum step size of the resistance divider is 10kW | ||||||||
Main test items | Power supply detection long - term load, switching device life test | ||||||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, wind pressure protection, emergency stop and other protection functions | ||||||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | ||||||||
Noise | ≤85dB | ≤86dB | ≤88dB | ||||||
Air Outlet Mode | Wind in from the side down and out from the top. | ||||||||
Display Accuracy | 0.1V,0.1A | ||||||||
Control Mode | Local manual control: through the load bank 7 inch LCD touch screen. | ||||||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | ||||||||
Place of Use | Indoor | Indoor/Outdoor | |||||||
Weight | 3500kg | 4200kg | 6500kg | 7500kg | 9200kg | 11500kg | |||
Size | L2991mm×W2438mm×H2896mm | L6058mm×W2438mm×H2896mm | L7500mm×W2438mm×H2896mm | L9000mm×W2438mm×H2896mm | L12192mm×W2438mm×H2896mm |
Name | Container medium voltage resistance inductive load -RL | |||
Model | IMAX4130-1500k | IMAX4130-2000k | IMAX4130-3000k | IMAX4130-4000k |
Rated Voltage | 3P4W,AC6.3kV/6.6kV/10kV/11kV/13.8kV | |||
Resistive Power | 1200kW | 1600kW | 2400kW | 3200kW |
Inductive power | 900kVar | 1200kVar | 1800kVar | 2400kVar |
Rated Frequency | 50/60Hz | |||
Loading Mode | Step loading | |||
power factor | 0.8-1 | |||
Load Stepping | The minimum dividing step is 10kW/7.5kVar | |||
Main test items | Generator set testing | |||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, wind pressure protection, emergency stop and other protection functions | |||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | |||
Noise | ≤85dB | ≤86dB | ||
Air Outlet Mode | Wind in from the side down and out from the top. | |||
Display Accuracy | 0.1V,0.1A | |||
Control Mode | Local manual control: through the load bank 7 inch LCD touch screen. | |||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||
Place of Use | Indoor | Indoor/Outdoor | ||
Weight | 9500kg | 14000kg | 16500kg | 19000kg |
Size | L4500mm×W2438mm×H2896mm | L9000mm×W2438mm×H2896mm 9m container | L12192mm×W2438mm×H2896mm |
Name |
Pressure resistance capacity load in container -RC
| ||||
Model | IMAX4130-1500k | IMAX4130-2000k | IMAX4130-3000k | IMAX4130-4000k | |
Rated Voltage | 3P4W,AC6.3kV/6.6kV/10kV/11kV/13.8kV | ||||
Resistive Power | 1200kW | 1600kW | 2400kW | 3200kW | |
Inductive power | 900kVar | 1200kVar | 1800kVar | 2400kVar | |
Rated Frequency | 50/60Hz | ||||
Loading Mode | Step loading | ||||
power factor | 0.8-1 | ||||
Load Stepping | The minimum dividing step is 10kW/7.5kVar | ||||
Main test items | Generator set testing | ||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, wind pressure protection, emergency stop and other protection functions | ||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | ||||
Noise | ≤85dB | ≤86dB | |||
Air Outlet Mode | Wind in from the side down and out from the top | ||||
Display Accuracy | 0.1V,0.1A | ||||
Control Mode | Local manual control: through the load bank 7 inch LCD touch screen. | ||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | ||||
Place of Use | Indoor | Indoor/Outdoor | |||
Weight | 9500kg | 14000kg | 16500kg | 19000kg | |
Size | L4500mm×W2438mm×H2896mm 4.5m container | L9000mm×W2438mm×H2896mm 9m container | L12192mm×W2438mm×H2896mm |