IMAX4100 series low pressure container load is mainly a comprehensive test load box. The main feature of this series of load bank is to meet the outdoor all-weather use, 7*24 hours long-term use, easy to move lifting use. The load box voltage unit of this series is 36V-1500V, and the power unit of a single unit is 1000kW-6000kW. Multiple units can be used simultaneously to meet the high power range.
Availability: | |
---|---|
Quantity: | |
IMAX4100 Series
Product Features&Advantage
1. Can meet long-term outdoor use;
2. High power density, far exceeding the average power density of peers;
3. RS485, Ethernet, CAN and other communication ports
4. The test steps are programmable, suitable for diesel generator set, gas generator set, anti-reverse power transmission, automatic test
5. Can load any power within the full power range, any power factor, test and display three-phase voltage, current, power, power factor;
6 Power adjustment accuracy: 1kW
7. Power factor adjustable: PF=0.8/1/0.4 and other power factor products can be customized
8. Use PC data management software to control load loading and load unloading, and save test data
Product Features&Advantage
1. Can meet long-term outdoor use;
2. High power density, far exceeding the average power density of peers;
3. RS485, Ethernet, CAN and other communication ports
4. The test steps are programmable, suitable for diesel generator set, gas generator set, anti-reverse power transmission, automatic test
5. Can load any power within the full power range, any power factor, test and display three-phase voltage, current, power, power factor;
6 Power adjustment accuracy: 1kW
7. Power factor adjustable: PF=0.8/1/0.4 and other power factor products can be customized
8. Use PC data management software to control load loading and load unloading, and save test data
Name | Container low voltage pure resistance load -R | |||||
Model | IMAX4110-1500k | IMAX4110-2000k | IMAX4110-3000k | IMAX4110-4000k | IMAX4110-5000k | IMAX4110-6000k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V/480V/690V/1140V | |||||
Resistive Power | 1500kW | 2000kW | 3000kW | 4000kW | 5000kW | 6000kW |
Rated Frequency | 50/60Hz | |||||
Loading Mode | Step loading | |||||
power factor | 1 | |||||
Load Stepping | The minimum resistance step length is 1kW | |||||
Main test items | Power supply detection long - term load, switching device life test | |||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, wind pressure protection, emergency stop and other protection functions | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | |||||
Noise | ≤85dB | ≤86dB | ≤88dB | |||
Air Outlet Mode | Wind in from the side down and out from the top. | |||||
Display Accuracy | 0.1V,0.1A | |||||
Control Mode | Local manual control: through the load bank 7 inch LCD touch screen. | |||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||||
Place of Use | Indoor | Indoor/Outdoor | ||||
Weight | 3500kg | 4200kg | 6500kg | 7500kg | 9200kg | 11500kg |
Size | L2991mm×W2438mm×H2896mm | L6058mm×W2438mm×H2896mm | L12192mm×W2438mm×H2896mm |
Name | Container low voltage resistance load -RL | |||||
Model | IMAX4130-1500k | IMAX4130-2000k | IMAX4130-3000k | IMAX4130-4000k | IMAX4130-5000k | IMAX4130-6000k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V/480V/690V/1140V | |||||
Resistive Power | 1200kW | 1600kW | 2400kW | 3200kW | 4000kW | 6000kW |
Inductive power | 900kVar | 1200kVar | 1800kVar | 2400kVar | 3000kVar | 600kVar |
Rated Frequency | 50/60Hz | |||||
Loading Mode | Step loading | |||||
power factor | 0.8-1 | |||||
Load Stepping | The minimum dividing step is 1kW/1kVar | |||||
Main test items | Power supply detection long - term load, switching device life test | |||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, wind pressure protection, emergency stop and other protection functions | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | |||||
Noise | ≤85dB | ≤86dB | ≤88dB | |||
Air Outlet Mode | Wind in from the side down and out from the top. | |||||
Display Accuracy | 0.1V,0.1A | |||||
Control Mode | Local manual control: through the load bank 7 inch LCD touch screen. | |||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||||
Place of Use | Indoor | Indoor/Outdoor | ||||
Weight | 9500kg | 12000kg | 16500kg | 19000kg | 23000kg | 26000kg |
Size | L2991mm×W2438mm×H2896mm | L3500mm×W2438mm×H2896mm | L6058mm×W2438mm×H2896mm | L9000mm×W2438mm×H2896mm | L12192mm×W2438mm×H2896mm |
Name | Container low voltage resistance capacity load -RLC | |||||
Model | IMAX4130-1000k | IMAX4130-1500k | IMAX4130-2500k | IMAX4130-3000k | IMAX4130-4000k | IMAX4130-5000k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V/480V/690V/1140V | |||||
Resistive Power | 800kW | 1200kW | 2000kW | 2400kW | 3200kW | 4000kW |
Inductive power | 600kVar | 900kVar | 1500kVar | 1800kVar | 2400kVar | 3000kVar |
Capacitive Power | 600kVar | 900kVar | 1500kVar | 1800kVar | 2400kVar | 3000kVar |
Rated Frequency | 50/60Hz | |||||
Loading Mode | Step loading | |||||
power factor | ±0.8-1 | |||||
Load Stepping | The minimum dividing step is 1kW/1kVar | |||||
Power supply detection long - term load, switching device life test | ||||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, wind pressure protection, emergency stop and other protection functions | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | |||||
Noise | ≤85dB | ≤86dB | ≤88dB | |||
Air Outlet Mode | Wind in from the side down and out from the top. | |||||
Display Accuracy | 0.1V,0.1A | |||||
Control Mode | Local manual control: through the load bank 7 inch LCD touch screen. | |||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||||
Place of Use | Indoor | Indoor/Outdoor | ||||
Weight | 8500kg | 11000kg | 13500kg | 16000kg | 19000kg | 23000kg |
Size | L2991mm×W2438mm×H2896mm | L3500mm×W2438mm×H2896mm | L6058mm×W2438mm×H2896mm | L9000mm×W2438mm×H2896mm | L12192mm×W2438mm×H2896mm |
Name | Container low voltage pure resistance load -R | |||||
Model | IMAX4110-1500k | IMAX4110-2000k | IMAX4110-3000k | IMAX4110-4000k | IMAX4110-5000k | IMAX4110-6000k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V/480V/690V/1140V | |||||
Resistive Power | 1500kW | 2000kW | 3000kW | 4000kW | 5000kW | 6000kW |
Rated Frequency | 50/60Hz | |||||
Loading Mode | Step loading | |||||
power factor | 1 | |||||
Load Stepping | The minimum resistance step length is 1kW | |||||
Main test items | Power supply detection long - term load, switching device life test | |||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, wind pressure protection, emergency stop and other protection functions | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | |||||
Noise | ≤85dB | ≤86dB | ≤88dB | |||
Air Outlet Mode | Wind in from the side down and out from the top. | |||||
Display Accuracy | 0.1V,0.1A | |||||
Control Mode | Local manual control: through the load bank 7 inch LCD touch screen. | |||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||||
Place of Use | Indoor | Indoor/Outdoor | ||||
Weight | 3500kg | 4200kg | 6500kg | 7500kg | 9200kg | 11500kg |
Size | L2991mm×W2438mm×H2896mm | L6058mm×W2438mm×H2896mm | L12192mm×W2438mm×H2896mm |
Name | Container low voltage resistance load -RL | |||||
Model | IMAX4130-1500k | IMAX4130-2000k | IMAX4130-3000k | IMAX4130-4000k | IMAX4130-5000k | IMAX4130-6000k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V/480V/690V/1140V | |||||
Resistive Power | 1200kW | 1600kW | 2400kW | 3200kW | 4000kW | 6000kW |
Inductive power | 900kVar | 1200kVar | 1800kVar | 2400kVar | 3000kVar | 600kVar |
Rated Frequency | 50/60Hz | |||||
Loading Mode | Step loading | |||||
power factor | 0.8-1 | |||||
Load Stepping | The minimum dividing step is 1kW/1kVar | |||||
Main test items | Power supply detection long - term load, switching device life test | |||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, wind pressure protection, emergency stop and other protection functions | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | |||||
Noise | ≤85dB | ≤86dB | ≤88dB | |||
Air Outlet Mode | Wind in from the side down and out from the top. | |||||
Display Accuracy | 0.1V,0.1A | |||||
Control Mode | Local manual control: through the load bank 7 inch LCD touch screen. | |||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||||
Place of Use | Indoor | Indoor/Outdoor | ||||
Weight | 9500kg | 12000kg | 16500kg | 19000kg | 23000kg | 26000kg |
Size | L2991mm×W2438mm×H2896mm | L3500mm×W2438mm×H2896mm | L6058mm×W2438mm×H2896mm | L9000mm×W2438mm×H2896mm | L12192mm×W2438mm×H2896mm |
Name | Container low voltage resistance capacity load -RLC | |||||
Model | IMAX4130-1000k | IMAX4130-1500k | IMAX4130-2500k | IMAX4130-3000k | IMAX4130-4000k | IMAX4130-5000k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V/480V/690V/1140V | |||||
Resistive Power | 800kW | 1200kW | 2000kW | 2400kW | 3200kW | 4000kW |
Inductive power | 600kVar | 900kVar | 1500kVar | 1800kVar | 2400kVar | 3000kVar |
Capacitive Power | 600kVar | 900kVar | 1500kVar | 1800kVar | 2400kVar | 3000kVar |
Rated Frequency | 50/60Hz | |||||
Loading Mode | Step loading | |||||
power factor | ±0.8-1 | |||||
Load Stepping | The minimum dividing step is 1kW/1kVar | |||||
Power supply detection long - term load, switching device life test | ||||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, wind pressure protection, emergency stop and other protection functions | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | |||||
Noise | ≤85dB | ≤86dB | ≤88dB | |||
Air Outlet Mode | Wind in from the side down and out from the top. | |||||
Display Accuracy | 0.1V,0.1A | |||||
Control Mode | Local manual control: through the load bank 7 inch LCD touch screen. | |||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||||
Place of Use | Indoor | Indoor/Outdoor | ||||
Weight | 8500kg | 11000kg | 13500kg | 16000kg | 19000kg | 23000kg |
Size | L2991mm×W2438mm×H2896mm | L3500mm×W2438mm×H2896mm | L6058mm×W2438mm×H2896mm | L9000mm×W2438mm×H2896mm | L12192mm×W2438mm×H2896mm |