Introducing the 7KW AC Load Bank for Charging Pile Testing – a precision-engineered solution tailored for verifying the performance and reliability of EV charging stations. Designed for robustness and ease of use, this load bank provides accurate simulation of real-world conditions, ensuring your charging piles are up to the task of delivering efficient and safe charging to electric vehicles.
This load bank boasts a power capacity of 7KW, making it ideal for a wide range of testing scenarios. It features a user-friendly interface, advanced safety mechanisms, and high-quality components that guarantee reliable performance over extended periods. Its compact and portable design allows for convenient transportation and deployment across various testing sites, providing a versatile tool for engineers and technicians.
The 7KW AC Load Bank is equipped with state-of-the-art monitoring systems, enabling real-time data collection and analysis. This feature ensures precise measurement of key parameters such as voltage, current, and power output, facilitating comprehensive testing and validation of charging pile functionality. The load bank's compatibility with various charging protocols ensures it can be used with a broad spectrum of charging stations, making it a valuable asset for any EV infrastructure project.
Availability: | |
---|---|
Quantity: | |
1.Enhanced Testing Accuracy
The 7KW AC Load Bank delivers precise simulation of charging conditions, enabling thorough evaluation of charging pile performance. This accuracy ensures that all potential issues are identified and addressed, resulting in more reliable and efficient charging stations.
2.Comprehensive Data Collection
Equipped with advanced monitoring systems, the load bank provides real-time data on voltage, current, and power output. This comprehensive data collection facilitates detailed analysis and ensures that every aspect of the charging pile’s performance is meticulously examined.
3.Portability and Flexibility
Its compact and lightweight construction allows for easy transportation, making it perfect for on-site testing. The load bank’s versatility means it can be used in various testing environments, ensuring that all charging piles meet the required standards regardless of location.
4.Compatibility with Multiple Protocols
This load bank supports a wide range of charging protocols, making it suitable for testing various types of charging piles. Its compatibility ensures that it can be used across different EV infrastructure projects, providing a versatile solution for all your testing needs.
By integrating the 7KW AC Load Bank into your testing regimen, you ensure that your charging stations are equipped to handle the demands of modern electric vehicles, ultimately contributing to a more robust and reliable EV charging infrastructure.
1.Enhanced Testing Accuracy
The 7KW AC Load Bank delivers precise simulation of charging conditions, enabling thorough evaluation of charging pile performance. This accuracy ensures that all potential issues are identified and addressed, resulting in more reliable and efficient charging stations.
2.Comprehensive Data Collection
Equipped with advanced monitoring systems, the load bank provides real-time data on voltage, current, and power output. This comprehensive data collection facilitates detailed analysis and ensures that every aspect of the charging pile’s performance is meticulously examined.
3.Portability and Flexibility
Its compact and lightweight construction allows for easy transportation, making it perfect for on-site testing. The load bank’s versatility means it can be used in various testing environments, ensuring that all charging piles meet the required standards regardless of location.
4.Compatibility with Multiple Protocols
This load bank supports a wide range of charging protocols, making it suitable for testing various types of charging piles. Its compatibility ensures that it can be used across different EV infrastructure projects, providing a versatile solution for all your testing needs.
By integrating the 7KW AC Load Bank into your testing regimen, you ensure that your charging stations are equipped to handle the demands of modern electric vehicles, ultimately contributing to a more robust and reliable EV charging infrastructure.
Name | Single phase pure resistance load -R | ||
Model | IMAX3110-30k | IMAX3110-50k | IMAX3110-100k |
Rated Voltage | 1P2W,AC230V/220V/110V | ||
Resistive Power | 33kW | 55kW | 110kW |
Rated Frequency | 50/60Hz | 50/60Hz | 50/60Hz |
Loading Mode | Step and shift loading | ||
Load Characteristic | Pure Resistance | ||
Load Stepping | The minimum resistance step size is 0.1kW | ||
Main test items | Power supply detection long - term load, switching device life test | ||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | ||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | ||
Noise | ≤70dB | ≤73dB | ≤75dB |
Air Outlet Mode | Side wind in, side wind out | Wind in from the side down and out from the top. | |
Display Accuracy | 0.1V,0.1A | ||
Control Mode | Local manual control: Local button/air switch/touch screen control | ||
Remote intelligent control: RS485/CAN/ Ethernet | |||
Place of Use | Indoor | ||
Weight | 50kg | 75kg | 150kg |
Size | W600mm×D800mm×H800mm | W600mm×D800mm×H1400mm | W600mm×D800mm×H1600mm |
Name | Three-phase pure resistance load -R | |||||
Model | IMAX3130-50k | IMAX3130-100k | IMAX3130-300k | IMAX3130-500k | IMAX3130-700k | IMAX3130-1000k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V | |||||
Resistive Power | 55kW | 110kW | 310kW | 510kW | 710kW | 1030kW |
Rated Frequency | 50/60Hz | |||||
Loading Mode | Step loading | |||||
Load Characteristic | pure resistance | |||||
Load Stepping | The minimum step size of the resistance divider is 10W | |||||
Main test items | Power supply detection long - term load, switching device life test | |||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | |||||
Noise | ≤75dB | ≤79dB | ≤82dB | |||
Air Outlet Mode | Wind in from the side down and out from the top | Side down ejection/side in side out | Wind in from the side down and out from the top | |||
Display Accuracy | 0.1V,0.1A | |||||
Control Mode | Local manual control: local button/circuit breaker | Local manual control: through the load box 7 inch LCD touch screen. | ||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||||
Place of Use | Indoor | Indoor/Outdoor | ||||
Weight | 80kg | 120kg | 450kg | 650kg | 950kg | 1300kg |
Size | W600mm×D800mm×H1400mm | W600mm×D800mm×H1600mm | sideward :W1500mm×D1300mm×H1400mm ejection:W1200mm*D1200mm*1800mm | sideward :W1750mm×D1300mm×H1400mm | W1200mm×D1400mm×H2000mm | W1800mm×D1200mm×H2000mm |
Name | Single phase pure resistance load -R | ||
Model | IMAX3110-30k | IMAX3110-50k | IMAX3110-100k |
Rated Voltage | 1P2W,AC230V/220V/110V | ||
Resistive Power | 33kW | 55kW | 110kW |
Rated Frequency | 50/60Hz | 50/60Hz | 50/60Hz |
Loading Mode | Step and shift loading | ||
Load Characteristic | Pure Resistance | ||
Load Stepping | The minimum resistance step size is 0.1kW | ||
Main test items | Power supply detection long - term load, switching device life test | ||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | ||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | ||
Noise | ≤70dB | ≤73dB | ≤75dB |
Air Outlet Mode | Side wind in, side wind out | Wind in from the side down and out from the top. | |
Display Accuracy | 0.1V,0.1A | ||
Control Mode | Local manual control: Local button/air switch/touch screen control | ||
Remote intelligent control: RS485/CAN/ Ethernet | |||
Place of Use | Indoor | ||
Weight | 50kg | 75kg | 150kg |
Size | W600mm×D800mm×H800mm | W600mm×D800mm×H1400mm | W600mm×D800mm×H1600mm |
Name | Three-phase pure resistance load -R | |||||
Model | IMAX3130-50k | IMAX3130-100k | IMAX3130-300k | IMAX3130-500k | IMAX3130-700k | IMAX3130-1000k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V | |||||
Resistive Power | 55kW | 110kW | 310kW | 510kW | 710kW | 1030kW |
Rated Frequency | 50/60Hz | |||||
Loading Mode | Step loading | |||||
Load Characteristic | pure resistance | |||||
Load Stepping | The minimum step size of the resistance divider is 10W | |||||
Main test items | Power supply detection long - term load, switching device life test | |||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | |||||
Noise | ≤75dB | ≤79dB | ≤82dB | |||
Air Outlet Mode | Wind in from the side down and out from the top | Side down ejection/side in side out | Wind in from the side down and out from the top | |||
Display Accuracy | 0.1V,0.1A | |||||
Control Mode | Local manual control: local button/circuit breaker | Local manual control: through the load box 7 inch LCD touch screen. | ||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||||
Place of Use | Indoor | Indoor/Outdoor | ||||
Weight | 80kg | 120kg | 450kg | 650kg | 950kg | 1300kg |
Size | W600mm×D800mm×H1400mm | W600mm×D800mm×H1600mm | sideward :W1500mm×D1300mm×H1400mm ejection:W1200mm*D1200mm*1800mm | sideward :W1750mm×D1300mm×H1400mm | W1200mm×D1400mm×H2000mm | W1800mm×D1200mm×H2000mm |