The 200KW AC Resistive Load Bank is a high-capacity, reliable, and user-friendly solution designed to meet the demanding requirements of power system testing. Its advanced features, robust construction, and enhanced safety mechanisms make it an indispensable tool for professionals in the field. Ensure your power systems are tested accurately and efficiently with this top-of-the-line load bank, and experience the peace of mind that comes with knowing your equipment is performing at its best.
Availability: | |
---|---|
Quantity: | |
IMAX3520-200KW
EMAX
20230729008
The 200KW AC Resistive Load Bank is engineered to deliver consistent and reliable performance. Its robust design and high-quality components ensure it operates effectively even under continuous use, providing accurate and repeatable results for every test.
Product Features&Advantage:
1.High Capacity: This load bank offers a substantial 200KW load capacity, making it ideal for heavy-duty applications and extensive testing scenarios.
2.Precision Testing: Equipped with advanced controls, it provides accurate load testing with precise measurements and reliable data output.
3.Safety Mechanisms: Enhanced safety features, including overload protection, emergency stop, and temperature monitoring, ensure safe operation at all times.
4.Portability: Designed with mobility in mind, the load bank features wheels and a compact design, allowing for easy transport and deployment across various locations.
The 200KW AC Resistive Load Bank is versatile and suitable for a wide range of applications, including:
Generator Testing: Validate the performance and reliability of generators under different load conditions.
UPS System Verification: Ensure uninterrupted power supply systems are functioning correctly by simulating real-world load conditions.
Power Supply Testing: Test and verify power supplies in industrial, commercial, and residential settings.
Maintenance and Troubleshooting: Identify and resolve issues in power systems through controlled load application and precise diagnostics.
The 200KW AC Resistive Load Bank is engineered to deliver consistent and reliable performance. Its robust design and high-quality components ensure it operates effectively even under continuous use, providing accurate and repeatable results for every test.
Product Features&Advantage:
1.High Capacity: This load bank offers a substantial 200KW load capacity, making it ideal for heavy-duty applications and extensive testing scenarios.
2.Precision Testing: Equipped with advanced controls, it provides accurate load testing with precise measurements and reliable data output.
3.Safety Mechanisms: Enhanced safety features, including overload protection, emergency stop, and temperature monitoring, ensure safe operation at all times.
4.Portability: Designed with mobility in mind, the load bank features wheels and a compact design, allowing for easy transport and deployment across various locations.
The 200KW AC Resistive Load Bank is versatile and suitable for a wide range of applications, including:
Generator Testing: Validate the performance and reliability of generators under different load conditions.
UPS System Verification: Ensure uninterrupted power supply systems are functioning correctly by simulating real-world load conditions.
Power Supply Testing: Test and verify power supplies in industrial, commercial, and residential settings.
Maintenance and Troubleshooting: Identify and resolve issues in power systems through controlled load application and precise diagnostics.
Selection | Three phase AC test load box | |
IMAX3520 | ||
Test circuit | type | Three-phase AC |
voltage | AC400V-50Hz/60Hz AC400V-400Hz | |
Wiring method | 3P4W | |
frequency | 50Hz | |
maximum power | 400V-50Hz:200kW/150kVar; 400V-60Hz:200kW/125kVar; 400V-400Hz:20kW/15kVar; | |
PF | 1/0.8 | |
Step accuracy | 0.5kW/0.375kVar | |
Load accuracy | ±3% | |
Wiring method | Copper bar | |
control loop | voltage | AC380V±10% |
frequency | 50Hz | |
Wiring method | 3P3W | |
power | <2.5kW | |
Power supply method | External power supply | |
Display accuracy | Level 0.5 | |
control mode | Remote software control, contactor switching. | |
communication interface | RS485 | |
Wiring method | Terminal | |
Box | Working mode | Continuous operation,7*24H |
Insulation level | F | |
Cooling method | Forced air cooling, side inlet, side outlet | |
Protection level | IP23 | |
Color | RAL7035,can be customized according to requirements | |
size | W1400mm×D1600mm×H1800mm | |
weight | 850kg | |
Mobile Method | Bottom with casters and top with lifting rings for easy movement | |
Protection function | Emergency stop | It can be manually forced to unload with one click, and cannot be loaded in the emergency stop locked state. |
temperature alarm | When the load temperature exceeds the safety threshold, a load alarm will be triggered. | |
Fan interlocking protection | The fan has not been turned on, and the load cannot be loaded. | |
Fan phase sequence protection | The phase sequence of the fan is connected incorrectly, and the fan can also operate normally. | |
Grounding protection | In order to avoid the risk of electric shock caused by the casing being damaged during load operation, the load cabinet is equipped with a dedicated grounding protection terminal. | |
Customized features | Sudden addition and removal function | Configure generator specific test 8961C2 for transient performance testing and data report printing |
Selection | Three phase AC test load box | |
IMAX3520 | ||
Test circuit | type | Three-phase AC |
voltage | AC400V-50Hz/60Hz AC400V-400Hz | |
Wiring method | 3P4W | |
frequency | 50Hz | |
maximum power | 400V-50Hz:200kW/150kVar; 400V-60Hz:200kW/125kVar; 400V-400Hz:20kW/15kVar; | |
PF | 1/0.8 | |
Step accuracy | 0.5kW/0.375kVar | |
Load accuracy | ±3% | |
Wiring method | Copper bar | |
control loop | voltage | AC380V±10% |
frequency | 50Hz | |
Wiring method | 3P3W | |
power | <2.5kW | |
Power supply method | External power supply | |
Display accuracy | Level 0.5 | |
control mode | Remote software control, contactor switching. | |
communication interface | RS485 | |
Wiring method | Terminal | |
Box | Working mode | Continuous operation,7*24H |
Insulation level | F | |
Cooling method | Forced air cooling, side inlet, side outlet | |
Protection level | IP23 | |
Color | RAL7035,can be customized according to requirements | |
size | W1400mm×D1600mm×H1800mm | |
weight | 850kg | |
Mobile Method | Bottom with casters and top with lifting rings for easy movement | |
Protection function | Emergency stop | It can be manually forced to unload with one click, and cannot be loaded in the emergency stop locked state. |
temperature alarm | When the load temperature exceeds the safety threshold, a load alarm will be triggered. | |
Fan interlocking protection | The fan has not been turned on, and the load cannot be loaded. | |
Fan phase sequence protection | The phase sequence of the fan is connected incorrectly, and the fan can also operate normally. | |
Grounding protection | In order to avoid the risk of electric shock caused by the casing being damaged during load operation, the load cabinet is equipped with a dedicated grounding protection terminal. | |