Home / Products / Resistive Load Bank / Resistive Load Bank for sale

Product Category

PRODUCT DETAIL

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Resistive Load Bank for sale

Our resistive load bank for sale is the ideal solution for testing and maintaining the performance of your power systems. It provides accurate simulation of real-world loads, ensuring your generators and UPS systems can handle operational demands. With precise measurements of voltage, current, and power, this load bank helps identify potential issues before they cause failures.

Availability:
Quantity:
  • IMAX2925-200KW

  • EMAX

Product Introduction:


This load bank is used for AC power supply testing and can test AC power supply, alternator, etc. The load bank is divided into 2 groups of independent load bank, and the incoming lines of the 2 load groups are each equipped with 4 incoming workstations for selection and switching (a total of 8 incoming workstations).

Product Advantage:

1. Can meet long-term outdoor use;

2. Provide the upper computer operating software

3. RS485, Ethernet, CAN and other communication ports

4. The test steps are programmable, suitable for diesel generator set, gas generator set, anti-reverse power transmission, automatic test

5. Can load any power within the full power range, any power factor, test and display three-phase voltage, current, power, power factor;

6 Power adjustment accuracy: 1kW

7. Use PC data management software to control load loading and load unloading and save test data

Product Parameters

Type

AC pure resistance load box

Model

IMAX2925

Voltage

AC530V-AC100V(line voltage)

Wiring method

6P6W (two way 3P3W)

Maximum power

2-way 200kW, automatically variable power for use, as shown in the power curve below.

Maximum current

404A, used with automatic variable power, as shown in the current curve below.

Power factor

1

Number of load circuits

1 three-phase ,3P3W

Number of incoming circuits

4 in 1 (connected to 4 sets of tested sources, polling operation mode)

Load classification

530V-200kW-2.8Ω;

350V-200kW-1.2Ω;

250V-200kW-0.6Ω;

100V-140kW-0.14Ω。

Load accuracy

±3%

Wiring method

copper bar (with silver paint sprayed on the end face)

Voltage

AC380V±10%

Frequency

50Hz

Wiring method

three-phase four wire system

Power

<4kW

Power supply method

external power supply

Display function

temperature display, 2-way voltage and current output

Loading method

The load box automatically recognizes voltage interruptions and loads the load automatically.

Communication interface

Ethernet/RS485, Modbu RTU protocol. The specific agreement can be modified as required.

Control method

1. Emergency stop start control: After pressing the emergency stop button, the device will automatically pull the load based on the current voltage;


2. Fan maintenance button: For daily maintenance, manually start the fan and observe if it is working properly;


3. Short circuit start at the dry output point: Short circuit start signal at the dry output point, and the device will automatically load based on the current voltage


Load, can be connected to normally open dry contact signals such as smoke alarm and over temperature alarm;


4. Communication control start stop: By writing a start stop signal through communication, the device will automatically start loading based on the current voltage


Load, while monitoring the current voltage, current, load gear feedback, equipment status, and other information of the equipment;


5. When the equipment starts, close the 1-4 circuit breakers in sequence, and when the current voltage is detected to be lower than the set value, hold the


After 1 minute, automatically switch to the next set of test circuits.


6. Operation priority, emergency stop button operation>dry contact control>remote communication control.

Wiring method

Terminal block

Working mode

Continuous operation

Insulation level

F

Cooling method

forced air cooling, side to side air inlet, rear air outlet.

Noise

≤ 85dB at 1 meter.

Protection level

IP54, outdoor rainproof.

IP54, outdoor rainproof

Cabinet color: RAL7035; Base: RLA9004.

Size

2000mm*1200mm*2200mm(width * depth * height)

Weight

890kg

Moving method

There are forklift holes at the bottom of the equipment

Temperature alarm

The device has a level 2 temperature alarm. The first level temperature alarm only sounds a buzzer, while the second level temperature alarm buzzer sounds and unloads the load, and outputs a dry node signal to the outside.

Smoke temperature alarm

A smoke temperature detector is installed on the top of the cabinet, which can provide smoke alarm and output alarm dry node signals to the outside

Short circuit protection

equipped with incoming circuit breaker (for live operation)

Fan interlocking

Without starting the fan, the load cannot be pulled.

Fan phase sequence protection

Built in phase sequence conversion switch, when voltage phase sequence error is detected, the fan can also start in the normal direction.

Fan air volume protection

The device is equipped with a built-in air pressure switch. When insufficient fan air pressure is detected, the load is stopped and fed back to the upper computer.

Low temperature start

The control room inside the load cabinet is relatively isolated from the outside, and a heater is installed to meet the starting condition of low temperature -40 ℃

Grounding protection

In order to avoid the risk of electric shock when the load is working, the load cabinet is equipped with a dedicated grounding protection terminal.

Withstand voltage characteristics

Resistance to ground: AC3KV, 50Hz, 1 minute, no breakdown, no flying fox

Insulation characteristics

DC1KV, insulation greater than 10MΩ


Models&Specifications

 

Name

Single phase resistive load -RL

Model

IMAX3210-25k

IMAX3210-50k

IMAX3210-100k

Rated Voltage

1P2WAC230V/220V/110V

Resistive Power

20kW

40kW

80kW

Inductive power

15kVar

30kVar

75kVar

Rated Frequency

50/60Hz

50/60Hz

50/60Hz

Loading Mode

Step and shift loading

Load Characteristic

Integrated resistance

Load Stepping

The minimum resistance step size is 0.1kW/0.1kVar

Main test items

Power supply detection long - term load, switching device life test

Protection Alarm

Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions.

Measurement and Control Parameter

Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions.

Noise

≤70dB

≤73dB

≤75dB

Air Outlet Mode

· 

Side wind in, side wind out

 

· 

Wind in from the side down and out from the top

 

Display Accuracy

0.1V0.1A

Control Mode

Local manual control: Local button/air switch/touch screen control

Remote intelligent control: RS485/CAN/ Ethernet

Place of Use

Indoor

Weight

120kg

220kg

350kg

Size

W600mm×D800mm×H800mm

W800mm×D800mm×H1400mm

W800mm×D800mm×H1600mm

 

 


 

Name

Three-phase resistive load -RL

Model

IMAX3230-125k

IMAX3230-250k

IMAX3230-500k

IMAX3230-625k

IMAX3230-750k

IMAX3230-1000k

Rated Voltage

3P4WAC220V/380V/400V/415V/440V

Resistive Power

100kW

200kW

400kW

500kW

600kW

800kW

Inductive power

75kVar

150kVar

300kVar

375kVar

450kVar

600kVar

Rated Frequency

50/60Hz

Loading Mode

Step loading

Load Characteristic

Integrated resistance

Load Stepping

The minimum resistance step length is 1kW/1kVar

Main test items

Power supply detection long - term load, switching device life test

Protection Alarm

Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions.

Measurement and Control Parameter

Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions.

Noise

≤75dB

≤80dB

≤85dB

Air Outlet Mode

Wind in from the side down and out from the top.

Side down ejection/side in side out

Wind in from the side down and out from the top.

Display Accuracy

0.1V0.1A

Control Mode

Local manual control: Local button/air switch

Local manual control: through the load box 7 inch LCD touch screen.

Remote intelligent control: RS485/CAN/ Ethernet

Remote intelligent control: RS485/CAN/ Ethernet

Place of Use

Indoor

Indoor/Outdoor

Weight

350kg

650kg

1100kg

1350kg

1650kg

2300kg

Size

W800mm×D800mm×H1600mm

W1000mm×D1200mm×H1600mm

W1200mm*D1400mm*1800mm


W1400mm*D1600mm*H1800mm

W1800mm×D1600mm×H2000mm

W2000mm×D1800mm×H2000mm


Previous: 
Next: 
Inquiry

Products

Navigation

Contact us

  +86-769-8831-6780
  +86-15099752515(Mr. Jiang)
   sales05@emaxgroups.com
    No. 94, Shangzha Road, Houjie Town, Dongguan, Guangdong
Send Us A Message
Copyright @2022 Guangdong Emax Electrical Co., Ltd. All Rights Reserved. Sitemap Support By Leadong Privacy Policy