Our resistive load bank for sale is the ideal solution for testing and maintaining the performance of your power systems. It provides accurate simulation of real-world loads, ensuring your generators and UPS systems can handle operational demands. With precise measurements of voltage, current, and power, this load bank helps identify potential issues before they cause failures.
Availability: | |
---|---|
Quantity: | |
IMAX2925-200KW
EMAX
This load bank is used for AC power supply testing and can test AC power supply, alternator, etc. The load bank is divided into 2 groups of independent load bank, and the incoming lines of the 2 load groups are each equipped with 4 incoming workstations for selection and switching (a total of 8 incoming workstations).
1. Can meet long-term outdoor use;
2. Provide the upper computer operating software
3. RS485, Ethernet, CAN and other communication ports
4. The test steps are programmable, suitable for diesel generator set, gas generator set, anti-reverse power transmission, automatic test
5. Can load any power within the full power range, any power factor, test and display three-phase voltage, current, power, power factor;
6 Power adjustment accuracy: 1kW
7. Use PC data management software to control load loading and load unloading and save test data
Type | AC pure resistance load box |
Model | IMAX2925 |
Voltage | AC530V-AC100V(line voltage) |
Wiring method | 6P6W (two way 3P3W) |
Maximum power | 2-way 200kW, automatically variable power for use, as shown in the power curve below. |
Maximum current | 404A, used with automatic variable power, as shown in the current curve below. |
Power factor | 1 |
Number of load circuits | 1 three-phase ,3P3W |
Number of incoming circuits | 4 in 1 (connected to 4 sets of tested sources, polling operation mode) |
Load classification | 530V-200kW-2.8Ω; 350V-200kW-1.2Ω; 250V-200kW-0.6Ω; 100V-140kW-0.14Ω。 |
Load accuracy | ±3% |
Wiring method | copper bar (with silver paint sprayed on the end face) |
Voltage | AC380V±10% |
Frequency | 50Hz |
Wiring method | three-phase four wire system |
Power | <4kW |
Power supply method | external power supply |
Display function | temperature display, 2-way voltage and current output |
Loading method | The load box automatically recognizes voltage interruptions and loads the load automatically. |
Communication interface | Ethernet/RS485, Modbu RTU protocol. The specific agreement can be modified as required. |
Control method | 1. Emergency stop start control: After pressing the emergency stop button, the device will automatically pull the load based on the current voltage; 2. Fan maintenance button: For daily maintenance, manually start the fan and observe if it is working properly; 3. Short circuit start at the dry output point: Short circuit start signal at the dry output point, and the device will automatically load based on the current voltage Load, can be connected to normally open dry contact signals such as smoke alarm and over temperature alarm; 4. Communication control start stop: By writing a start stop signal through communication, the device will automatically start loading based on the current voltage Load, while monitoring the current voltage, current, load gear feedback, equipment status, and other information of the equipment; 5. When the equipment starts, close the 1-4 circuit breakers in sequence, and when the current voltage is detected to be lower than the set value, hold the After 1 minute, automatically switch to the next set of test circuits. 6. Operation priority, emergency stop button operation>dry contact control>remote communication control. |
Wiring method | Terminal block |
Working mode | Continuous operation |
Insulation level | F |
Cooling method | forced air cooling, side to side air inlet, rear air outlet. |
Noise | ≤ 85dB at 1 meter. |
Protection level | IP54, outdoor rainproof. |
IP54, outdoor rainproof | Cabinet color: RAL7035; Base: RLA9004. |
Size | 2000mm*1200mm*2200mm(width * depth * height) |
Weight | 890kg |
Moving method | There are forklift holes at the bottom of the equipment |
Temperature alarm | The device has a level 2 temperature alarm. The first level temperature alarm only sounds a buzzer, while the second level temperature alarm buzzer sounds and unloads the load, and outputs a dry node signal to the outside. |
Smoke temperature alarm | A smoke temperature detector is installed on the top of the cabinet, which can provide smoke alarm and output alarm dry node signals to the outside |
Short circuit protection | equipped with incoming circuit breaker (for live operation) |
Fan interlocking | Without starting the fan, the load cannot be pulled. |
Fan phase sequence protection | Built in phase sequence conversion switch, when voltage phase sequence error is detected, the fan can also start in the normal direction. |
Fan air volume protection | The device is equipped with a built-in air pressure switch. When insufficient fan air pressure is detected, the load is stopped and fed back to the upper computer. |
Low temperature start | The control room inside the load cabinet is relatively isolated from the outside, and a heater is installed to meet the starting condition of low temperature -40 ℃ |
Grounding protection | In order to avoid the risk of electric shock when the load is working, the load cabinet is equipped with a dedicated grounding protection terminal. |
Withstand voltage characteristics | Resistance to ground: AC3KV, 50Hz, 1 minute, no breakdown, no flying fox |
Insulation characteristics | DC1KV, insulation greater than 10MΩ |
This load bank is used for AC power supply testing and can test AC power supply, alternator, etc. The load bank is divided into 2 groups of independent load bank, and the incoming lines of the 2 load groups are each equipped with 4 incoming workstations for selection and switching (a total of 8 incoming workstations).
1. Can meet long-term outdoor use;
2. Provide the upper computer operating software
3. RS485, Ethernet, CAN and other communication ports
4. The test steps are programmable, suitable for diesel generator set, gas generator set, anti-reverse power transmission, automatic test
5. Can load any power within the full power range, any power factor, test and display three-phase voltage, current, power, power factor;
6 Power adjustment accuracy: 1kW
7. Use PC data management software to control load loading and load unloading and save test data
Type | AC pure resistance load box |
Model | IMAX2925 |
Voltage | AC530V-AC100V(line voltage) |
Wiring method | 6P6W (two way 3P3W) |
Maximum power | 2-way 200kW, automatically variable power for use, as shown in the power curve below. |
Maximum current | 404A, used with automatic variable power, as shown in the current curve below. |
Power factor | 1 |
Number of load circuits | 1 three-phase ,3P3W |
Number of incoming circuits | 4 in 1 (connected to 4 sets of tested sources, polling operation mode) |
Load classification | 530V-200kW-2.8Ω; 350V-200kW-1.2Ω; 250V-200kW-0.6Ω; 100V-140kW-0.14Ω。 |
Load accuracy | ±3% |
Wiring method | copper bar (with silver paint sprayed on the end face) |
Voltage | AC380V±10% |
Frequency | 50Hz |
Wiring method | three-phase four wire system |
Power | <4kW |
Power supply method | external power supply |
Display function | temperature display, 2-way voltage and current output |
Loading method | The load box automatically recognizes voltage interruptions and loads the load automatically. |
Communication interface | Ethernet/RS485, Modbu RTU protocol. The specific agreement can be modified as required. |
Control method | 1. Emergency stop start control: After pressing the emergency stop button, the device will automatically pull the load based on the current voltage; 2. Fan maintenance button: For daily maintenance, manually start the fan and observe if it is working properly; 3. Short circuit start at the dry output point: Short circuit start signal at the dry output point, and the device will automatically load based on the current voltage Load, can be connected to normally open dry contact signals such as smoke alarm and over temperature alarm; 4. Communication control start stop: By writing a start stop signal through communication, the device will automatically start loading based on the current voltage Load, while monitoring the current voltage, current, load gear feedback, equipment status, and other information of the equipment; 5. When the equipment starts, close the 1-4 circuit breakers in sequence, and when the current voltage is detected to be lower than the set value, hold the After 1 minute, automatically switch to the next set of test circuits. 6. Operation priority, emergency stop button operation>dry contact control>remote communication control. |
Wiring method | Terminal block |
Working mode | Continuous operation |
Insulation level | F |
Cooling method | forced air cooling, side to side air inlet, rear air outlet. |
Noise | ≤ 85dB at 1 meter. |
Protection level | IP54, outdoor rainproof. |
IP54, outdoor rainproof | Cabinet color: RAL7035; Base: RLA9004. |
Size | 2000mm*1200mm*2200mm(width * depth * height) |
Weight | 890kg |
Moving method | There are forklift holes at the bottom of the equipment |
Temperature alarm | The device has a level 2 temperature alarm. The first level temperature alarm only sounds a buzzer, while the second level temperature alarm buzzer sounds and unloads the load, and outputs a dry node signal to the outside. |
Smoke temperature alarm | A smoke temperature detector is installed on the top of the cabinet, which can provide smoke alarm and output alarm dry node signals to the outside |
Short circuit protection | equipped with incoming circuit breaker (for live operation) |
Fan interlocking | Without starting the fan, the load cannot be pulled. |
Fan phase sequence protection | Built in phase sequence conversion switch, when voltage phase sequence error is detected, the fan can also start in the normal direction. |
Fan air volume protection | The device is equipped with a built-in air pressure switch. When insufficient fan air pressure is detected, the load is stopped and fed back to the upper computer. |
Low temperature start | The control room inside the load cabinet is relatively isolated from the outside, and a heater is installed to meet the starting condition of low temperature -40 ℃ |
Grounding protection | In order to avoid the risk of electric shock when the load is working, the load cabinet is equipped with a dedicated grounding protection terminal. |
Withstand voltage characteristics | Resistance to ground: AC3KV, 50Hz, 1 minute, no breakdown, no flying fox |
Insulation characteristics | DC1KV, insulation greater than 10MΩ |
Name | Single phase resistive load -RL | ||
Model | IMAX3210-25k | IMAX3210-50k | IMAX3210-100k |
Rated Voltage | 1P2W,AC230V/220V/110V | ||
Resistive Power | 20kW | 40kW | 80kW |
Inductive power | 15kVar | 30kVar | 75kVar |
Rated Frequency | 50/60Hz | 50/60Hz | 50/60Hz |
Loading Mode | Step and shift loading | ||
Integrated resistance | |||
Load Stepping | The minimum resistance step size is 0.1kW/0.1kVar | ||
Main test items | Power supply detection long - term load, switching device life test | ||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | ||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | ||
Noise | ≤70dB | ≤73dB | ≤75dB |
Air Outlet Mode | · Side wind in, side wind out
| · Wind in from the side down and out from the top
| |
Display Accuracy | 0.1V,0.1A | ||
Control Mode | Local manual control: Local button/air switch/touch screen control | ||
Remote intelligent control: RS485/CAN/ Ethernet | |||
Place of Use | Indoor | ||
Weight | 120kg | 220kg | 350kg |
Size | W600mm×D800mm×H800mm | W800mm×D800mm×H1400mm | W800mm×D800mm×H1600mm |
Name | Three-phase resistive load -RL | |||||
Model | IMAX3230-125k | IMAX3230-250k | IMAX3230-500k | IMAX3230-625k | IMAX3230-750k | IMAX3230-1000k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V | |||||
Resistive Power | 100kW | 200kW | 400kW | 500kW | 600kW | 800kW |
Inductive power | 75kVar | 150kVar | 300kVar | 375kVar | 450kVar | 600kVar |
Rated Frequency | 50/60Hz | |||||
Loading Mode | Step loading | |||||
Load Characteristic | Integrated resistance | |||||
Load Stepping | The minimum resistance step length is 1kW/1kVar | |||||
Main test items | Power supply detection long - term load, switching device life test | |||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | |||||
Noise | ≤75dB | ≤80dB | ≤85dB | |||
Air Outlet Mode | Wind in from the side down and out from the top. | Side down ejection/side in side out | Wind in from the side down and out from the top. | |||
Display Accuracy | 0.1V,0.1A | |||||
Control Mode | Local manual control: Local button/air switch | Local manual control: through the load box 7 inch LCD touch screen. | ||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||||
Place of Use | Indoor | Indoor/Outdoor | ||||
Weight | 350kg | 650kg | 1100kg | 1350kg | 1650kg | 2300kg |
Size | W800mm×D800mm×H1600mm | W1000mm×D1200mm×H1600mm | W1200mm*D1400mm*1800mm |
| W1800mm×D1600mm×H2000mm | W2000mm×D1800mm×H2000mm |
Name | Single phase resistive load -RL | ||
Model | IMAX3210-25k | IMAX3210-50k | IMAX3210-100k |
Rated Voltage | 1P2W,AC230V/220V/110V | ||
Resistive Power | 20kW | 40kW | 80kW |
Inductive power | 15kVar | 30kVar | 75kVar |
Rated Frequency | 50/60Hz | 50/60Hz | 50/60Hz |
Loading Mode | Step and shift loading | ||
Integrated resistance | |||
Load Stepping | The minimum resistance step size is 0.1kW/0.1kVar | ||
Main test items | Power supply detection long - term load, switching device life test | ||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | ||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | ||
Noise | ≤70dB | ≤73dB | ≤75dB |
Air Outlet Mode | · Side wind in, side wind out
| · Wind in from the side down and out from the top
| |
Display Accuracy | 0.1V,0.1A | ||
Control Mode | Local manual control: Local button/air switch/touch screen control | ||
Remote intelligent control: RS485/CAN/ Ethernet | |||
Place of Use | Indoor | ||
Weight | 120kg | 220kg | 350kg |
Size | W600mm×D800mm×H800mm | W800mm×D800mm×H1400mm | W800mm×D800mm×H1600mm |
Name | Three-phase resistive load -RL | |||||
Model | IMAX3230-125k | IMAX3230-250k | IMAX3230-500k | IMAX3230-625k | IMAX3230-750k | IMAX3230-1000k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V | |||||
Resistive Power | 100kW | 200kW | 400kW | 500kW | 600kW | 800kW |
Inductive power | 75kVar | 150kVar | 300kVar | 375kVar | 450kVar | 600kVar |
Rated Frequency | 50/60Hz | |||||
Loading Mode | Step loading | |||||
Load Characteristic | Integrated resistance | |||||
Load Stepping | The minimum resistance step length is 1kW/1kVar | |||||
Main test items | Power supply detection long - term load, switching device life test | |||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | |||||
Noise | ≤75dB | ≤80dB | ≤85dB | |||
Air Outlet Mode | Wind in from the side down and out from the top. | Side down ejection/side in side out | Wind in from the side down and out from the top. | |||
Display Accuracy | 0.1V,0.1A | |||||
Control Mode | Local manual control: Local button/air switch | Local manual control: through the load box 7 inch LCD touch screen. | ||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||||
Place of Use | Indoor | Indoor/Outdoor | ||||
Weight | 350kg | 650kg | 1100kg | 1350kg | 1650kg | 2300kg |
Size | W800mm×D800mm×H1600mm | W1000mm×D1200mm×H1600mm | W1200mm*D1400mm*1800mm |
| W1800mm×D1600mm×H2000mm | W2000mm×D1800mm×H2000mm |