Key Features:
Durable Container Design: Ensures protection against environmental factors, enhancing longevity and reliability.
Advanced Digital Controls: Facilitates precise load management and monitoring.
Scalable Load Capacity: Supports a range of load testing requirements, from small to large-scale applications.
Safety Features: Includes over-temperature protection, emergency stop, and more to ensure safe operation.
Portability: Easy to transport and deploy, suitable for various testing environments.
Product Advantages:
Enhanced Reliability and Safety
The Medium Voltage Load Banks - Container Load Bank is engineered with safety as a top priority. It includes features like over-temperature protection and emergency stop, ensuring safe operation during all testing scenarios. Its robust container design protects internal components from harsh environmental conditions, ensuring consistent and reliable performance.
Versatile and Scalable
This load bank is designed to accommodate a wide range of load testing requirements, making it a versatile choice for various applications. Whether you need to test smaller systems or larger, more complex power setups, the Medium Voltage Load Bank can be easily configured to meet your specific needs.
Advanced Control Systems
With state-of-the-art digital controls, this load bank offers precise load management and real-time monitoring. Operators can easily adjust settings and monitor performance through an intuitive interface, ensuring accurate and efficient testing.
Portability and Convenience
Housed in a container, this load bank is highly portable and can be easily transported to different locations. Its compact design does not compromise its performance, making it a convenient solution for both temporary and permanent installations.
Optimized Performance
Designed for medium voltage applications, this load bank ensures optimal performance under various load conditions. It provides accurate and reliable data, crucial for optimizing the efficiency and reliability of electrical power systems.
Name | Container medium pressure pure resistance load -R | ||||||||
Model | IMAX4510-1000k | IMAX4510-2000k | IMAX4510-2500k | IMAX4510-3000k | IMAX4510-4000k | IMAX4510-5000k | |||
Rated Voltage | 3P4W,AC6.3kV/6.6kV/10kV/11kV/13.8kV | ||||||||
Resistive Power | 1000kW | 2000kW | 2500kW | 3000kW | 4000kW | 5000kW | |||
Rated Frequency | 50/60Hz | ||||||||
Loading Mode | Step loading | ||||||||
power factor | 1 | ||||||||
Load Stepping | The minimum step size of the resistance divider is 10kW | ||||||||
Main test items | Power supply detection long - term load, switching device life test | ||||||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, wind pressure protection, emergency stop and other protection functions | ||||||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | ||||||||
Noise | ≤85dB | ≤86dB | ≤88dB | ||||||
Air Outlet Mode | Wind in from the side down and out from the top. | ||||||||
Display Accuracy | 0.1V,0.1A | ||||||||
Control Mode | Local manual control: through the load bank 7 inch LCD touch screen. | ||||||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | ||||||||
Place of Use | Indoor | Indoor/Outdoor | |||||||
Weight | 3500kg | 4200kg | 6500kg | 7500kg | 9200kg | 11500kg | |||
Size | L2991mm×W2438mm×H2896mm | L6058mm×W2438mm×H2896mm | L7500mm×W2438mm×H2896mm | L9000mm×W2438mm×H2896mm | L12192mm×W2438mm×H2896mm |
Name | Container medium voltage resistance inductive load -RL | |||
Model | IMAX4130-1500k | IMAX4130-2000k | IMAX4130-3000k | IMAX4130-4000k |
Rated Voltage | 3P4W,AC6.3kV/6.6kV/10kV/11kV/13.8kV | |||
Resistive Power | 1200kW | 1600kW | 2400kW | 3200kW |
Inductive power | 900kVar | 1200kVar | 1800kVar | 2400kVar |
Rated Frequency | 50/60Hz | |||
Loading Mode | Step loading | |||
power factor | 0.8-1 | |||
Load Stepping | The minimum dividing step is 10kW/7.5kVar | |||
Main test items | Generator set testing | |||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, wind pressure protection, emergency stop and other protection functions | |||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | |||
Noise | ≤85dB | ≤86dB | ||
Air Outlet Mode | Wind in from the side down and out from the top. | |||
Display Accuracy | 0.1V,0.1A | |||
Control Mode | Local manual control: through the load bank 7 inch LCD touch screen. | |||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||
Place of Use | Indoor | Indoor/Outdoor | ||
Weight | 9500kg | 14000kg | 16500kg | 19000kg |
Size | L4500mm×W2438mm×H2896mm | L9000mm×W2438mm×H2896mm 9m container | L12192mm×W2438mm×H2896mm |
Name | Pressure resistance capacity load in container -RC
| ||||
Model | IMAX4130-1500k | IMAX4130-2000k | IMAX4130-3000k | IMAX4130-4000k | |
Rated Voltage | 3P4W,AC6.3kV/6.6kV/10kV/11kV/13.8kV | ||||
Resistive Power | 1200kW | 1600kW | 2400kW | 3200kW | |
Inductive power | 900kVar | 1200kVar | 1800kVar | 2400kVar | |
Rated Frequency | 50/60Hz | ||||
Loading Mode | Step loading | ||||
power factor | 0.8-1 | ||||
Load Stepping | The minimum dividing step is 10kW/7.5kVar | ||||
Main test items | Generator set testing | ||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, wind pressure protection, emergency stop and other protection functions | ||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | ||||
Noise | ≤85dB | ≤86dB | |||
Air Outlet Mode | Wind in from the side down and out from the top | ||||
Display Accuracy | 0.1V,0.1A | ||||
Control Mode | Local manual control: through the load bank 7 inch LCD touch screen. | ||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | ||||
Place of Use | Indoor | Indoor/Outdoor | |||
Weight | 9500kg | 14000kg | 16500kg | 19000kg | |
Size | L4500mm×W2438mm×H2896mm 4.5m container | L9000mm×W2438mm×H2896mm 9m container | L12192mm×W2438mm×H2896mm |