Product Description:
The 100KW-RCD Three-phase Non-linear Load Bank is an indispensable tool for professionals requiring precise and reliable load testing. Its advanced features, robust design, and versatility make it suitable for a wide range of applications, ensuring optimal performance and safety. With proper maintenance and adherence to operational guidelines, this load bank will provide consistent and accurate results, contributing to the efficiency and reliability of your electrical systems.
The RCD Three-phase Non-linear Load Bank is versatile and can be utilized across multiple industries and scenarios:
Power Generation Plants: For testing the efficiency and stability of generators under non-linear load conditions.
Data Centers: To simulate server loads and validate the performance of UPS systems and power distribution units.
Industrial Facilities: For assessing the capacity and resilience of electrical installations.
Electrical Maintenance Services: Essential for routine maintenance checks and troubleshooting of power systems.
Educational Institutions: As a practical teaching aid for electrical engineering students.
High Precision Testing: Equipped with advanced control systems, the load bank provides highly accurate load simulation, ensuring reliable test results.
Versatile Load Simulation: Capable of simulating various load types, including resistive, inductive, and non-linear loads, providing comprehensive testing capabilities.
Safety Features: Integrated safety mechanisms, such as over-temperature protection and emergency shutdown, ensure safe operation at all times.
Efficient Cooling System: The load bank features an efficient cooling system that prevents overheating and ensures stable performance during extended testing periods.
Compact and Portable: Designed for ease of transport and setup, making it convenient for on-site testing and mobile operations.
Name | Three-Phase RCD load - Nonlinear load | |||||
Model | IMAX5330-15k | IMAX5330-30k | IMAX5330-45k | IMAX5330-60k | IMAX3510-100k | IMAX3510-200k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V | |||||
Working Voltage | Other voltages, wide voltages, or other mode can be customized | |||||
Max Power | 15kVA | 30kVA | 45kVA | 60kVA | 100kVA | 200kVA |
Rated Frequency | 50/60Hz | |||||
Power Factor (PF) | 0.6~1 adjustable,0.5 at least | |||||
Crest Factor(CF) | 2~3adjustable | |||||
Step accuracy | 100W/50W/25W Optional | |||||
Load classification | A Phase:0.1k/0.2k/0.5k/1k/2k/5k/other | |||||
B Phase:0.1k/0.2k/0.5k/1k/2k/5k/other | ||||||
C Phase:0.1k/0.2k/0.5k/1k/2k/5k/other | ||||||
Customizable: three single-phase/one single-phase/three-phase independent, maximum power does not exceed total power | ||||||
Load Function | R load test, RCD load test, total load switch, short circuit function is optional | |||||
Main Testing Items | Portable energy storage power supply, outdoor energy storage power supply, home energy storage power supply, photovoltaic inverter load test, UPS power supply test, other nonlinear load test requirements | |||||
Protection Alarm | Ground protection, high temperature fault, emergency stop and other protection functions. | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | |||||
Noise | ≤72dB | ≤75dB | ≤78dB | |||
Air Outlet Mode | Wind in from the side down and out from the top. | |||||
Display Accuracy | 0.1V,0.1A,PF(0.01) | |||||
Control Mode | Manual: Button/circuit breaker control | |||||
Local manual control: through 7 inch LCD touch screen of load bank | ||||||
Remote intelligent control: RS485, (the protocol is Modbus-RTU, and the upper computer software is provided.) | ||||||
Place of Use | Indoor | Indoor/Outdoor | ||||
Weight | 150kg | 230kg | 280kg | 320kg | 400kg | 480kg |
Size | W800mm×D600mm×H1600mm | W1000mm×D1200mm×H1850mm | W1200mm×D1400mm×H2000mm |
Name | Single-phase RCD load | ||
Model | IMAX5310-5k | IMAX5310-10k | IMAX3510-15k |
Rated Voltage | 1P2W,220V/110V,Double voltage can be customized | ||
Max Power | 5kVA | 10kVA | 15kVA |
Rated Frequency | 50/60Hz | ||
Power Factor (PF) | 0.6~1(adjustable),0.45 at least | ||
Crest Factor(CF) | 2~3 | ||
Step accuracy | 100W/50W/25W Optional | ||
Load classification | 0.1k/0.2k/0.5k/1k/2k/5k/other | ||
Main Testing Items | Portable energy storage power supply, outdoor energy storage power supply, home energy storage power supply, photovoltaic inverter load test, UPS power supply test, other nonlinear load test requirements | ||
Protection Alarm | Ground protection, high temperature fault, emergency stop and other protection functions. | ||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | ||
Noise | ≤65dB | ≤70dB | ≤70dB |
Air Outlet Mode | Wind in from the front, out from the behind | Wind in from the side down and out from the top | Wind in from the side down and out from the top |
Display Accuracy | 0.1V,0.1A | ||
Control Mode | Manual: Button/circuit breaker control | ||
Local manual control: through 7 inch LCD touch screen of load bank | |||
Remote intelligent control: RS485, (the protocol is Modbus-RTU, and the upper computer software is provided.) |