Availability: | |
---|---|
Quantity: | |
IMAXS1260-120KW
EMAX
Product Description:
Our High Voltage DC Power Supply represents the pinnacle of performance, safety, and versatility. Whether for industrial, research, or testing applications, it delivers reliable and precise power tailored to your needs. With its robust design and advanced features, it ensures operational excellence and supports a wide range of high-voltage DC applications.
1. Industrial Applications:High Voltage DC Power Supplies are essential in industries where precise and high-voltage DC power is required for equipment testing, machinery operation, and electrochemical processes. They are frequently used in metal plating, semiconductor fabrication, and battery charging applications.
2. Research and Development:In R&D laboratories, these power supplies are invaluable for experimental setups that demand high-voltage DC sources. They facilitate studies in materials science, electrical engineering, and physics, where accurate voltage control is paramount.
3. Electrical Testing and Maintenance:For testing and maintaining high-voltage equipment such as transformers, circuit breakers, and insulators, our High Voltage DC Power Supply provides the stable and adjustable DC voltage necessary for thorough evaluation and troubleshooting.
4. Aerospace and Defense:In aerospace and defense sectors, where high reliability and precision are crucial, these power supplies support systems testing, component evaluations, and research into advanced technologies.
Product Description:
Our High Voltage DC Power Supply represents the pinnacle of performance, safety, and versatility. Whether for industrial, research, or testing applications, it delivers reliable and precise power tailored to your needs. With its robust design and advanced features, it ensures operational excellence and supports a wide range of high-voltage DC applications.
1. Industrial Applications:High Voltage DC Power Supplies are essential in industries where precise and high-voltage DC power is required for equipment testing, machinery operation, and electrochemical processes. They are frequently used in metal plating, semiconductor fabrication, and battery charging applications.
2. Research and Development:In R&D laboratories, these power supplies are invaluable for experimental setups that demand high-voltage DC sources. They facilitate studies in materials science, electrical engineering, and physics, where accurate voltage control is paramount.
3. Electrical Testing and Maintenance:For testing and maintaining high-voltage equipment such as transformers, circuit breakers, and insulators, our High Voltage DC Power Supply provides the stable and adjustable DC voltage necessary for thorough evaluation and troubleshooting.
4. Aerospace and Defense:In aerospace and defense sectors, where high reliability and precision are crucial, these power supplies support systems testing, component evaluations, and research into advanced technologies.
Model | IMAXS1260 | |
output parameter | Max Capacity | 120KW |
Voltage Range | DC50-200V | |
Rated Voltage | DC200V | |
Current Range | 0-600A | |
Voltage Ripple | ≤0.5%F.S(full scale) | |
Current Ripple | ≤0.5%F.S(full scale) | |
Voltage stabilization accuracy | ≤±0.5% F.S(FS Resistor Load) | |
Precision of steady current | ≤±1% F.S(FS Resistor Load) | |
Line Regulation | ±0.1% F.S | |
Load Regulation | ±0.3% F.S | |
Output Rise Time | <100mS(10%-90%)Resistive load test | |
Transient Response Time | <10s | |
Mode of Connection | Terminal | |
Uploading Shock | ≤0.5%rated value,time≤1s | |
Instantaneous drop with load | ≤0.5%rated value,time≤500ms | |
Insulation strength,insulation resistance | Input to housing:20MΩ 500VDC; Output to housing:20MΩ 500VDC | |
Anti-backfilling resistance | With Anti-backfilling resistance | |
Control Loop | Voltage | 380V±15% |
Input Method | Three phase four wire +PE | |
Frequency | 50Hz±10% | |
Control Mode | Local touch screen + remote hard wire start and emergency stop control box | |
Mode of Connection | Terminal | |
Power Supply Mode | External | |
Casing | Working Mode | Continuous working |
Insulation Grade | F Level | |
Cooling Mode | Intelligent speed fan, forced air cooling, forward air, after air. | |
Noise | ≤65dB at 1 meter | |
Size | About 500mm*700mm*1000mm(width * depth * height) | |
Weight | About 160kg | |
Moving method | There are casters on the bottom and handles on the front for easy movement. | |
Defensive Function | Voltage limiting, current limiting, over voltage, over current, over temperature overload, short circuit, Protection cut off output, shutdown self-discharge function | |
Other Function | Both input and output have pre-charging functions |
Model | IMAXS1260 | |
output parameter | Max Capacity | 120KW |
Voltage Range | DC50-200V | |
Rated Voltage | DC200V | |
Current Range | 0-600A | |
Voltage Ripple | ≤0.5%F.S(full scale) | |
Current Ripple | ≤0.5%F.S(full scale) | |
Voltage stabilization accuracy | ≤±0.5% F.S(FS Resistor Load) | |
Precision of steady current | ≤±1% F.S(FS Resistor Load) | |
Line Regulation | ±0.1% F.S | |
Load Regulation | ±0.3% F.S | |
Output Rise Time | <100mS(10%-90%)Resistive load test | |
Transient Response Time | <10s | |
Mode of Connection | Terminal | |
Uploading Shock | ≤0.5%rated value,time≤1s | |
Instantaneous drop with load | ≤0.5%rated value,time≤500ms | |
Insulation strength,insulation resistance | Input to housing:20MΩ 500VDC; Output to housing:20MΩ 500VDC | |
Anti-backfilling resistance | With Anti-backfilling resistance | |
Control Loop | Voltage | 380V±15% |
Input Method | Three phase four wire +PE | |
Frequency | 50Hz±10% | |
Control Mode | Local touch screen + remote hard wire start and emergency stop control box | |
Mode of Connection | Terminal | |
Power Supply Mode | External | |
Casing | Working Mode | Continuous working |
Insulation Grade | F Level | |
Cooling Mode | Intelligent speed fan, forced air cooling, forward air, after air. | |
Noise | ≤65dB at 1 meter | |
Size | About 500mm*700mm*1000mm(width * depth * height) | |
Weight | About 160kg | |
Moving method | There are casters on the bottom and handles on the front for easy movement. | |
Defensive Function | Voltage limiting, current limiting, over voltage, over current, over temperature overload, short circuit, Protection cut off output, shutdown self-discharge function | |
Other Function | Both input and output have pre-charging functions |