The High Voltage DC Load Bank is an advanced, reliable, and efficient testing solution designed for high-voltage DC power systems. It is meticulously engineered to cater to the needs of industries requiring precise load testing, including renewable energy, data centers, and power utility sectors. The High Voltage DC Load Bank provides unparalleled performance, ensuring that your power systems operate optimally and safely under various conditions.
Availability: | |
---|---|
Quantity: | |
TYPE: IMAX2130
Product Features
High Precision Testing:
Delivers accurate and reliable load testing for high-voltage DC power systems.
Supports a wide range of voltage and current settings to meet diverse testing requirements.
Robust Design:
Built with high-quality materials to withstand rigorous testing environments.
Durable construction ensures long-lasting performance and minimal maintenance.
Advanced Safety Features:
Includes comprehensive safety mechanisms such as over-voltage, over-current, and over-temperature protection.
Ensures the safety of both the operator and the equipment during testing procedures.
User-Friendly Interface:
Equipped with an intuitive control panel and digital display for easy operation.
Provides real-time data monitoring and precise control over load settings.
Versatile Applications:
Ideal for testing batteries, power supplies, and other high-voltage DC equipment.
Suitable for use in various industries, including renewable energy, telecommunications, and manufacturing.
Technical Specifications
Voltage Range: Up to 1000V DC
Current Range: Up to 1000A DC
Power Capacity: Up to 1 MW
Cooling Method: Forced air cooling
Safety Standards: Compliant with international safety standards (CE, UL, etc.)
TYPE: IMAX2130
Product Features
High Precision Testing:
Delivers accurate and reliable load testing for high-voltage DC power systems.
Supports a wide range of voltage and current settings to meet diverse testing requirements.
Robust Design:
Built with high-quality materials to withstand rigorous testing environments.
Durable construction ensures long-lasting performance and minimal maintenance.
Advanced Safety Features:
Includes comprehensive safety mechanisms such as over-voltage, over-current, and over-temperature protection.
Ensures the safety of both the operator and the equipment during testing procedures.
User-Friendly Interface:
Equipped with an intuitive control panel and digital display for easy operation.
Provides real-time data monitoring and precise control over load settings.
Versatile Applications:
Ideal for testing batteries, power supplies, and other high-voltage DC equipment.
Suitable for use in various industries, including renewable energy, telecommunications, and manufacturing.
Technical Specifications
Voltage Range: Up to 1000V DC
Current Range: Up to 1000A DC
Power Capacity: Up to 1 MW
Cooling Method: Forced air cooling
Safety Standards: Compliant with international safety standards (CE, UL, etc.)
Name | General purpose DC load | |||||
Model | IMAX2100-30k | IMAX2100-50k | IMAX2100-100k | IMAX2100-200k | IMAX2100-300k | IMAX2100-500k |
Rated Voltage | 5V/60V/240V/750V/1000V arbitrary DC voltage etc. | |||||
Power | 30kW | 50kW | 100kW | 200kW | 300kW | 500kW |
Loading Mode | Step and shift loading | |||||
Load Characteristic | pure resistance | |||||
Load Stepping | 1mA/1W at least | |||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | |||||
Measurement and Control Parameter | Voltage, current | |||||
Noise | ≤70dB | ≤73dB | ≤75dB | ≤76dB | ≤77dB | ≤78dB |
Air Outlet Mode |
Side wind in, side wind out
| Wind in from the side down and out from the top | Side wind in, side wind out
| Wind in from the side down and out from the top
| ||
Display Accuracy | 0.1V,0.1A | 0.1V,0.1A | ||||
Control Mode | Local manual control: Local button/air switch/touch screen control | Local manual control: Local button/air switch/touch screen control | ||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||||
Place of Use | Indoor | Indoor | ||||
Weight | 50kg | 75kg | 150kg | 250kg | 425kg | 650kg |
Size | W600mm×D800mm×H800mm | W600mm×D800mm×H1400mm | W600mm×D800mm×H1600mm | W800mm×D800mm×H1800mm | : W1500mm×D1300mm×H1400mm | sideward: W1750mm×D1300mm×H1400mm W1200mm*D1400mm*H1800mm |
Name | General purpose DC load | |||||
Model | IMAX2100-30k | IMAX2100-50k | IMAX2100-100k | IMAX2100-200k | IMAX2100-300k | IMAX2100-500k |
Rated Voltage | 5V/60V/240V/750V/1000V arbitrary DC voltage etc. | |||||
Power | 30kW | 50kW | 100kW | 200kW | 300kW | 500kW |
Loading Mode | Step and shift loading | |||||
Load Characteristic | pure resistance | |||||
Load Stepping | 1mA/1W at least | |||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | |||||
Measurement and Control Parameter | Voltage, current | |||||
Noise | ≤70dB | ≤73dB | ≤75dB | ≤76dB | ≤77dB | ≤78dB |
Air Outlet Mode |
Side wind in, side wind out
| Wind in from the side down and out from the top | Side wind in, side wind out
| Wind in from the side down and out from the top
| ||
Display Accuracy | 0.1V,0.1A | 0.1V,0.1A | ||||
Control Mode | Local manual control: Local button/air switch/touch screen control | Local manual control: Local button/air switch/touch screen control | ||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||||
Place of Use | Indoor | Indoor | ||||
Weight | 50kg | 75kg | 150kg | 250kg | 425kg | 650kg |
Size | W600mm×D800mm×H800mm | W600mm×D800mm×H1400mm | W600mm×D800mm×H1600mm | W800mm×D800mm×H1800mm | : W1500mm×D1300mm×H1400mm | sideward: W1750mm×D1300mm×H1400mm W1200mm*D1400mm*H1800mm |