The 7kW Charging Pile Load Bank is a specialized, standalone testing device designed for verifying the performance and safety of electric vehicle (EV) charging stations. This load bank simulates real-world charging scenarios, ensuring that EV charging infrastructure operates efficiently and reliably under various load conditions. Ideal for manufacturers, service providers, and maintenance teams, this load bank is an essential tool for conducting routine checks, diagnostics, and certification of EV chargers.
Availability: | |
---|---|
Quantity: | |
IMAX1107-7KW
EMAX
Power Rating: 7kW Load Capacity
Supports single-phase 230V AC at 50/60Hz for comprehensive testing of standard EV charging stations.
Load Simulation:
Offers a precise load adjustment mechanism that simulates the charging process, enabling the testing of the charger’s capacity to handle varying loads.
Safety and Protection:
Equipped with multiple safety features, including overvoltage, overcurrent, and overtemperature protection, ensuring secure operation during testing.
Digital Display and Controls:
Integrated with an intuitive digital interface that displays real-time parameters such as voltage, current, power, and temperature, allowing for easy monitoring and adjustments.
Portability:
Compact and lightweight design with a durable carry handle, making it easy to transport and deploy on-site or in the lab.
Connectivity:
Includes standard connectors compatible with most EV chargers, with options for custom adapters based on specific requirements.
Cooling System:
Features a high-efficiency forced air cooling system that ensures stable operation during prolonged testing periods.
Durability:
Housed in a rugged, industrial-grade enclosure that protects the internal components from environmental factors, extending the product’s service life.
Compliance and Certification:
Complies with international safety and performance standards, ensuring reliable operation in diverse environments.
Charger Manufacturing: Ideal for end-of-line testing to ensure every unit meets performance and safety standards before deployment.
Service and Maintenance: Essential for routine testing and troubleshooting of installed EV charging stations in commercial and public spaces.
Research and Development: A valuable tool for R&D teams working on the development of new charging technologies or upgrading existing solutions.
Training: Useful for training technicians and engineers on the proper installation, maintenance, and troubleshooting of EV chargers
Power Rating: 7kW Load Capacity
Supports single-phase 230V AC at 50/60Hz for comprehensive testing of standard EV charging stations.
Load Simulation:
Offers a precise load adjustment mechanism that simulates the charging process, enabling the testing of the charger’s capacity to handle varying loads.
Safety and Protection:
Equipped with multiple safety features, including overvoltage, overcurrent, and overtemperature protection, ensuring secure operation during testing.
Digital Display and Controls:
Integrated with an intuitive digital interface that displays real-time parameters such as voltage, current, power, and temperature, allowing for easy monitoring and adjustments.
Portability:
Compact and lightweight design with a durable carry handle, making it easy to transport and deploy on-site or in the lab.
Connectivity:
Includes standard connectors compatible with most EV chargers, with options for custom adapters based on specific requirements.
Cooling System:
Features a high-efficiency forced air cooling system that ensures stable operation during prolonged testing periods.
Durability:
Housed in a rugged, industrial-grade enclosure that protects the internal components from environmental factors, extending the product’s service life.
Compliance and Certification:
Complies with international safety and performance standards, ensuring reliable operation in diverse environments.
Charger Manufacturing: Ideal for end-of-line testing to ensure every unit meets performance and safety standards before deployment.
Service and Maintenance: Essential for routine testing and troubleshooting of installed EV charging stations in commercial and public spaces.
Research and Development: A valuable tool for R&D teams working on the development of new charging technologies or upgrading existing solutions.
Training: Useful for training technicians and engineers on the proper installation, maintenance, and troubleshooting of EV chargers
Name | Single phase resistive load -RL | ||
Model | IMAX3210-25k | IMAX3210-50k | IMAX3210-100k |
Rated Voltage | 1P2W,AC230V/220V/110V | ||
Resistive Power | 20kW | 40kW | 80kW |
Inductive power | 15kVar | 30kVar | 75kVar |
Rated Frequency | 50/60Hz | 50/60Hz | 50/60Hz |
Loading Mode | Step and shift loading | ||
Load Characteristic | Integrated resistance | ||
Load Stepping | The minimum resistance step size is 0.1kW/0.1kVar | ||
Main test items | Power supply detection long - term load, switching device life test | ||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | ||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | ||
Noise | ≤70dB | ≤73dB | ≤75dB |
Air Outlet Mode | Side wind in, side wind out
| Wind in from the side down and out from the top
| |
Display Accuracy | 0.1V,0.1A | ||
Control Mode | Local manual control: Local button/air switch/touch screen control | ||
Remote intelligent control: RS485/CAN/ Ethernet | |||
Place of Use | Indoor | ||
Weight | 120kg | 220kg | 350kg |
Size | W600mm×D800mm×H800mm | W800mm×D800mm×H1400mm | W800mm×D800mm×H1600mm |
Name | Three-phase resistive load -RL | |||||
Model | IMAX3230-125k | IMAX3230-250k | IMAX3230-500k | IMAX3230-625k | IMAX3230-750k | IMAX3230-1000k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V | |||||
Resistive Power | 100kW | 200kW | 400kW | 500kW | 600kW | 800kW |
Inductive power | 75kVar | 150kVar | 300kVar | 375kVar | 450kVar | 600kVar |
Rated Frequency | 50/60Hz | |||||
Loading Mode | Step loading | |||||
Load Characteristic | Integrated resistance | |||||
Load Stepping | The minimum resistance step length is 1kW/1kVar | |||||
Main test items | Power supply detection long - term load, switching device life test | |||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | |||||
Noise | ≤75dB | ≤80dB | ≤85dB | |||
Air Outlet Mode | Wind in from the side down and out from the top. | Side down ejection/side in side out | Wind in from the side down and out from the top. | |||
Display Accuracy | 0.1V,0.1A | |||||
Control Mode | Local manual control: Local button/air switch | Local manual control: through the load box 7 inch LCD touch screen. | ||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||||
Place of Use | Indoor | Indoor/Outdoor | ||||
Weight | 350kg | 650kg | 1100kg | 1350kg | 1650kg | 2300kg |
Size | W800mm×D800mm×H1600mm | W1000mm×D1200mm×H1600mm | W1200mm*D1400mm*1800mm |
| W1800mm×D1600mm×H2000mm | W2000mm×D1800mm×H2000mm |
Name | Single phase resistive load -RL | ||
Model | IMAX3210-25k | IMAX3210-50k | IMAX3210-100k |
Rated Voltage | 1P2W,AC230V/220V/110V | ||
Resistive Power | 20kW | 40kW | 80kW |
Inductive power | 15kVar | 30kVar | 75kVar |
Rated Frequency | 50/60Hz | 50/60Hz | 50/60Hz |
Loading Mode | Step and shift loading | ||
Load Characteristic | Integrated resistance | ||
Load Stepping | The minimum resistance step size is 0.1kW/0.1kVar | ||
Main test items | Power supply detection long - term load, switching device life test | ||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | ||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | ||
Noise | ≤70dB | ≤73dB | ≤75dB |
Air Outlet Mode | Side wind in, side wind out
| Wind in from the side down and out from the top
| |
Display Accuracy | 0.1V,0.1A | ||
Control Mode | Local manual control: Local button/air switch/touch screen control | ||
Remote intelligent control: RS485/CAN/ Ethernet | |||
Place of Use | Indoor | ||
Weight | 120kg | 220kg | 350kg |
Size | W600mm×D800mm×H800mm | W800mm×D800mm×H1400mm | W800mm×D800mm×H1600mm |
Name | Three-phase resistive load -RL | |||||
Model | IMAX3230-125k | IMAX3230-250k | IMAX3230-500k | IMAX3230-625k | IMAX3230-750k | IMAX3230-1000k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V | |||||
Resistive Power | 100kW | 200kW | 400kW | 500kW | 600kW | 800kW |
Inductive power | 75kVar | 150kVar | 300kVar | 375kVar | 450kVar | 600kVar |
Rated Frequency | 50/60Hz | |||||
Loading Mode | Step loading | |||||
Load Characteristic | Integrated resistance | |||||
Load Stepping | The minimum resistance step length is 1kW/1kVar | |||||
Main test items | Power supply detection long - term load, switching device life test | |||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | |||||
Noise | ≤75dB | ≤80dB | ≤85dB | |||
Air Outlet Mode | Wind in from the side down and out from the top. | Side down ejection/side in side out | Wind in from the side down and out from the top. | |||
Display Accuracy | 0.1V,0.1A | |||||
Control Mode | Local manual control: Local button/air switch | Local manual control: through the load box 7 inch LCD touch screen. | ||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||||
Place of Use | Indoor | Indoor/Outdoor | ||||
Weight | 350kg | 650kg | 1100kg | 1350kg | 1650kg | 2300kg |
Size | W800mm×D800mm×H1600mm | W1000mm×D1200mm×H1600mm | W1200mm*D1400mm*1800mm |
| W1800mm×D1600mm×H2000mm | W2000mm×D1800mm×H2000mm |