The 300KW AC/DC Integrated Charging Pile Test Load Bank is a high-performance testing solution designed for comprehensive evaluation and quality assurance of electric vehicle (EV) charging infrastructure. Engineered to support both alternating current (AC) and direct current (DC) charging systems, this load bank is essential for manufacturers, testing facilities, and service providers focused on the development, production, and maintenance of advanced EV charging stations.
Availability: | |
---|---|
Quantity: | |
IMAX 3100 Series
R&D and Product Development: Ideal for manufacturers in the research and development phase of new charging pile designs, allowing for thorough testing before market release.
Production Line Testing: Ensures that charging piles meet specified performance criteria before leaving the factory, helping to maintain consistent product quality.
Field Service and Maintenance: Used by service teams for on-site testing and diagnostics of installed charging stations, ensuring optimal operation and identifying potential issues.
Compliance Testing: Supports regulatory compliance testing to ensure that charging piles meet local and international standards.
Power Capacity: 300KW (AC/DC)
Input Voltage Range: AC: 220V/380V, DC: 200V-1000V
Load Adjustment: Fine-tuned control, with step and continuous load adjustment
Cooling Method: Forced air/liquid cooling
Safety Features: Over-voltage, over-current, short-circuit protection, thermal management
Interface: Digital control panel with remote access capability
Data Logging: Integrated with real-time monitoring and data recording
The 300KW AC/DC Integrated Charging Pile Test Load Bank is an essential tool for any organization involved in the EV charging industry, offering unmatched flexibility, safety, and precision in testing high-power charging infrastructure.
R&D and Product Development: Ideal for manufacturers in the research and development phase of new charging pile designs, allowing for thorough testing before market release.
Production Line Testing: Ensures that charging piles meet specified performance criteria before leaving the factory, helping to maintain consistent product quality.
Field Service and Maintenance: Used by service teams for on-site testing and diagnostics of installed charging stations, ensuring optimal operation and identifying potential issues.
Compliance Testing: Supports regulatory compliance testing to ensure that charging piles meet local and international standards.
Power Capacity: 300KW (AC/DC)
Input Voltage Range: AC: 220V/380V, DC: 200V-1000V
Load Adjustment: Fine-tuned control, with step and continuous load adjustment
Cooling Method: Forced air/liquid cooling
Safety Features: Over-voltage, over-current, short-circuit protection, thermal management
Interface: Digital control panel with remote access capability
Data Logging: Integrated with real-time monitoring and data recording
The 300KW AC/DC Integrated Charging Pile Test Load Bank is an essential tool for any organization involved in the EV charging industry, offering unmatched flexibility, safety, and precision in testing high-power charging infrastructure.
Name | Single phase pure resistance load -R | ||
Model | IMAX3110-30k | IMAX3110-50k | IMAX3110-100k |
Rated Voltage | 1P2W,AC230V/220V/110V | ||
Resistive Power | 33kW | 55kW | 110kW |
Rated Frequency | 50/60Hz | 50/60Hz | 50/60Hz |
Loading Mode | Step and shift loading | ||
Load Characteristic | Pure Resistance | ||
Load Stepping | The minimum resistance step size is 0.1kW | ||
Main test items | Power supply detection long - term load, switching device life test | ||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | ||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | ||
Noise | ≤70dB | ≤73dB | ≤75dB |
Air Outlet Mode | Side wind in, side wind out | Wind in from the side down and out from the top. | |
Display Accuracy | 0.1V,0.1A | ||
Control Mode | Local manual control: Local button/air switch/touch screen control | ||
Remote intelligent control: RS485/CAN/ Ethernet | |||
Place of Use | Indoor | ||
Weight | 50kg | 75kg | 150kg |
Size | W600mm×D800mm×H800mm | W600mm×D800mm×H1400mm | W600mm×D800mm×H1600mm |
Name | Three-phase pure resistance load -R | |||||
Model | IMAX3130-50k | IMAX3130-100k | IMAX3130-300k | IMAX3130-500k | IMAX3130-700k | IMAX3130-1000k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V | |||||
Resistive Power | 55kW | 110kW | 310kW | 510kW | 710kW | 1030kW |
Rated Frequency | 50/60Hz | |||||
Loading Mode | Step loading | |||||
Load Characteristic | pure resistance | |||||
Load Stepping | The minimum step size of the resistance divider is 10W | |||||
Main test items | Power supply detection long - term load, switching device life test | |||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | |||||
Noise | ≤75dB | ≤79dB | ≤82dB | |||
Air Outlet Mode | Wind in from the side down and out from the top | Side down ejection/side in side out | Wind in from the side down and out from the top | |||
Display Accuracy | 0.1V,0.1A | |||||
Control Mode | Local manual control: local button/circuit breaker | Local manual control: through the load box 7 inch LCD touch screen. | ||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||||
Place of Use | Indoor | Indoor/Outdoor | ||||
Weight | 80kg | 120kg | 450kg | 650kg | 950kg | 1300kg |
Size | W600mm×D800mm×H1400mm | W600mm×D800mm×H1600mm | · sideward :W1500mm×D1300mm×H1400mm ejection:W1200mm*D1200mm*1800mm | sideward :W1750mm×D1300mm×H1400mm | W1200mm×D1400mm×H2000mm | W1800mm×D1200mm×H2000mm |
Name | Single phase pure resistance load -R | ||
Model | IMAX3110-30k | IMAX3110-50k | IMAX3110-100k |
Rated Voltage | 1P2W,AC230V/220V/110V | ||
Resistive Power | 33kW | 55kW | 110kW |
Rated Frequency | 50/60Hz | 50/60Hz | 50/60Hz |
Loading Mode | Step and shift loading | ||
Load Characteristic | Pure Resistance | ||
Load Stepping | The minimum resistance step size is 0.1kW | ||
Main test items | Power supply detection long - term load, switching device life test | ||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | ||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | ||
Noise | ≤70dB | ≤73dB | ≤75dB |
Air Outlet Mode | Side wind in, side wind out | Wind in from the side down and out from the top. | |
Display Accuracy | 0.1V,0.1A | ||
Control Mode | Local manual control: Local button/air switch/touch screen control | ||
Remote intelligent control: RS485/CAN/ Ethernet | |||
Place of Use | Indoor | ||
Weight | 50kg | 75kg | 150kg |
Size | W600mm×D800mm×H800mm | W600mm×D800mm×H1400mm | W600mm×D800mm×H1600mm |
Name | Three-phase pure resistance load -R | |||||
Model | IMAX3130-50k | IMAX3130-100k | IMAX3130-300k | IMAX3130-500k | IMAX3130-700k | IMAX3130-1000k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V | |||||
Resistive Power | 55kW | 110kW | 310kW | 510kW | 710kW | 1030kW |
Rated Frequency | 50/60Hz | |||||
Loading Mode | Step loading | |||||
Load Characteristic | pure resistance | |||||
Load Stepping | The minimum step size of the resistance divider is 10W | |||||
Main test items | Power supply detection long - term load, switching device life test | |||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | |||||
Noise | ≤75dB | ≤79dB | ≤82dB | |||
Air Outlet Mode | Wind in from the side down and out from the top | Side down ejection/side in side out | Wind in from the side down and out from the top | |||
Display Accuracy | 0.1V,0.1A | |||||
Control Mode | Local manual control: local button/circuit breaker | Local manual control: through the load box 7 inch LCD touch screen. | ||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||||
Place of Use | Indoor | Indoor/Outdoor | ||||
Weight | 80kg | 120kg | 450kg | 650kg | 950kg | 1300kg |
Size | W600mm×D800mm×H1400mm | W600mm×D800mm×H1600mm | · sideward :W1500mm×D1300mm×H1400mm ejection:W1200mm*D1200mm*1800mm | sideward :W1750mm×D1300mm×H1400mm | W1200mm×D1400mm×H2000mm | W1800mm×D1200mm×H2000mm |