Power Rating: 600kW total capacity, with configurable RLC load settings.
Voltage Rating: Three-phase 415V, compatible with standard industrial and commercial power systems.
Load Adjustability: Independent control of resistive, inductive, and capacitive load elements, allowing precise adjustment of power factor and testing conditions.
Cooling System: Integrated forced-air cooling with temperature monitoring and overheat protection for continuous operation.
Construction:
Heavy-duty enclosure with powder-coated steel for durability.
IP-rated protection for outdoor/indoor use.
Safety Features:
Overload and short-circuit protection.
Emergency stop button.
Insulated power connections.
Control Options:
Local control panel with analog/digital meters for real-time load and power factor monitoring.
Remote control capability via communication interfaces (e.g., Ethernet or RS485).
Load Components:
Resistive: Pure resistors to simulate active power loads.
Inductive: Reactors for reactive power simulation (lagging power factor).
Capacitive: Capacitors to simulate leading power factor loads.
Generator Testing: Ensures reliable operation under various load conditions.
Transformer Testing: Evaluates capacity and efficiency under combined RLC loads.
UPS Testing: Validates uninterruptible power supply performance.
Renewable Energy Systems: Simulates load dynamics for solar and wind power systems.
Power Factor Correction: Assess and optimize system power factor with adjustable RLC settings.
Rated Voltage: 415V AC, 3-phase, 50/60Hz.
Power Steps: Load increments for fine-tuning.
Power Factor Range: Adjustable from leading (capacitive) to lagging (inductive).
Operating Environment:
Temperature: -10°C to +50°C.
Humidity: <95% non-condensing.
This load bank is ideal for testing and commissioning power systems in industrial, commercial, and utility settings, providing robust, reliable, and accurate performance simulations.
1. Can conduct anti islanding tests
2. Provide upper computer operation software
3. Equipped with various communication interfaces such as RS485, Ethernet, CAN, etc
4. The test steps can be programmed, which is suitable for Test automation of Solar inverter and energy storage converter
5. It can load any power and any power factor within the full power range, test and display the three-phase voltage, current, power and quality factor of the generating set;
6. Power regulation accuracy: 1W/1Var
7. Control load loading and unloading through PC data management software and save test data
Name | Three-phase anti-island Load -RLC | |||||
Model | IMAX3510-400k | IMAX3510-600k | IMAX3510-800k | IMAX3510-1000k | IMAX3510-1600k | IMAX3510-2000k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V | |||||
Resistive Power | 400kW | 600kW | 800kW | 1000kW | 1600kW | 2000kW |
Inductive power | 400kVar | 600kVAR | 800kVAR | 1000kVAR | 1600kVAR | 2000kVAR |
Capacitive Power | 400kVar | 600kVAR | 800kVAR | 1000kVAR | 1600kVAR | 2000kVAR |
Rated Frequency | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz |
Loading Mode | Resistive capacitance independent adjustable | |||||
Load Characteristic | Resistive capacitance integrated load | |||||
Load Stepping | The minimum step size of the resistance divider is 10W | |||||
The minimum step size of perceptual classification is 10Var | ||||||
Capacitive divider step size minimum 10Var | ||||||
Main test items | Grid-connected inverter anti-island effect protection test, inverter efficiency test, power factor test, overload protection test | |||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, quality factor, power factor, frequency and other basic functions. | |||||
Noise | ≤78dB | ≤80dB | ≤85dB | |||
Air Outlet Mode | Wind in from the side down and out from the top. | |||||
Display Accuracy | 0.1V,0.1A | |||||
Control Mode | Local manual control: through the load box 7 inch LCD touch screen. | Local manual control: through the load box 10 inch LCD touch screen. | ||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||||
Place of Use | Indoor | Indoor/Outdoor | ||||
Weight | 3250kg | 5450kg | 6850kg | 7200kg | 8500kg | 9000kg |
Size | W2500mm×D2500mm×H12200mm | W2991mm×D2438mm×H2591mm 10 foot container | W6058mm×D2438mm×H2591mm 20 foot container |