Product Description:
Key features of the Best Container Load Bank include automated controls, user-friendly interfaces, and enhanced safety mechanisms. Its high capacity and versatility make it suitable for testing generators, UPS systems, and other power supply equipment, ensuring their optimal performance and reliability.
The Best Container Load Bank is versatile and can be used in various applications, including:
Power Generation Plants: Essential for periodic testing and maintenance of generators to ensure their efficiency and reliability.
Data Centers: Used for load testing of UPS systems to guarantee uninterrupted power supply.
Telecommunications: Ensures backup power systems are fully functional and reliable.
Marine and Offshore: Ideal for testing the power systems of ships and offshore platforms.
Renewable Energy: Useful for testing the load handling capacity of renewable energy sources like wind and solar power systems.
Military and Defense: Provides reliable load testing for critical power systems used in defense applications.
Manufacturing and Industrial: Ensures the reliability of backup power systems in manufacturing and industrial plants.
Durability and Portability: The containerized design offers robust protection and easy transportation, making it suitable for both permanent installations and temporary deployments.
Advanced Technology: Equipped with the latest technology, it provides precise load testing with high accuracy and reliability.
User-Friendly Interface: Simplifies operation with an intuitive control panel and automated testing procedures.
Enhanced Safety: Incorporates multiple safety mechanisms to protect both the load bank and the equipment being tested.
Versatility: Can handle a wide range of voltages and power capacities, making it suitable for diverse applications.
Cost-Effective: Reduces the need for multiple load banks by offering a wide range of testing capabilities in a single unit.
Comprehensive Data Logging: Provides detailed reports and data logging for thorough analysis and record-keeping.
When deploying the Best Container Load Bank, consider the following requirements:
Site Preparation: Ensure the site is level and capable of supporting the weight of the container. Proper ventilation and cooling systems should be in place to prevent overheating during operation.
Power Supply Compatibility: Verify that the load bank is compatible with the power supply systems being tested, including voltage and frequency specifications.
Safety Precautions: Implement necessary safety measures, including grounding and the use of protective equipment, to prevent accidents and ensure the safety of personnel.
Operational Training: Provide training for operators to ensure they are familiar with the controls and safety procedures associated with the load bank.
Maintenance: Regular maintenance and inspections should be conducted to ensure the load bank remains in optimal working condition.
Environmental Considerations: Take into account environmental factors such as temperature, humidity, and weather conditions that may impact the performance of the load bank.
By adhering to these requirements and leveraging the advanced features of the Best Container Load Bank, you can ensure reliable and efficient load testing for a wide range of applications, thereby enhancing the performance and reliability of your power systems.
Name | Container low voltage pure resistance load -R | |||||
Model | IMAX4110-1500k | IMAX4110-2000k | IMAX4110-3000k | IMAX4110-4000k | IMAX4110-5000k | IMAX4110-6000k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V/480V/690V/1140V | |||||
Resistive Power | 1500kW | 2000kW | 3000kW | 4000kW | 5000kW | 6000kW |
Rated Frequency | 50/60Hz | |||||
Loading Mode | Step loading | |||||
power factor | 1 | |||||
Load Stepping | The minimum resistance step length is 1kW | |||||
Main test items | Power supply detection long - term load, switching device life test | |||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, wind pressure protection, emergency stop and other protection functions | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | |||||
Noise | ≤85dB | ≤86dB | ≤88dB | |||
Air Outlet Mode | Wind in from the side down and out from the top. | |||||
Display Accuracy | 0.1V,0.1A | |||||
Control Mode | Local manual control: through the load bank 7 inch LCD touch screen. | |||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||||
Place of Use | Indoor | Indoor/Outdoor | ||||
Weight | 3500kg | 4200kg | 6500kg | 7500kg | 9200kg | 11500kg |
Size | L2991mm×W2438mm×H2896mm | L6058mm×W2438mm×H2896mm | L12192mm×W2438mm×H2896mm |
Name | Container low voltage resistance load -RL | |||||
Model | IMAX4130-1500k | IMAX4130-2000k | IMAX4130-3000k | IMAX4130-4000k | IMAX4130-5000k | IMAX4130-6000k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V/480V/690V/1140V | |||||
Resistive Power | 1200kW | 1600kW | 2400kW | 3200kW | 4000kW | 6000kW |
Inductive power | 900kVar | 1200kVar | 1800kVar | 2400kVar | 3000kVar | 600kVar |
Rated Frequency | 50/60Hz | |||||
Loading Mode | Step loading | |||||
power factor | 0.8-1 | |||||
Load Stepping | The minimum dividing step is 1kW/1kVar | |||||
Main test items | Power supply detection long - term load, switching device life test | |||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, wind pressure protection, emergency stop and other protection functions | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | |||||
Noise | ≤85dB | ≤86dB | ≤88dB | |||
Air Outlet Mode | Wind in from the side down and out from the top. | |||||
Display Accuracy | 0.1V,0.1A | |||||
Control Mode | Local manual control: through the load bank 7 inch LCD touch screen. | |||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||||
Place of Use | Indoor | Indoor/Outdoor | ||||
Weight | 9500kg | 12000kg | 16500kg | 19000kg | 23000kg | 26000kg |
Size | L2991mm×W2438mm×H2896mm | L3500mm×W2438mm×H2896mm | L6058mm×W2438mm×H2896mm | L9000mm×W2438mm×H2896mm | L12192mm×W2438mm×H2896mm |