The 5KW-RCD Load Bank is an advanced and reliable tool designed for testing and verifying the performance of power sources and backup systems. With a robust 5-kilowatt capacity, this load bank ensures that your generators, UPS systems, and other power sources are operating efficiently under real-world conditions.
5KW Load Capacity: Capable of simulating loads up to 5,000 watts, making it ideal for a wide range of applications, from small-scale testing to industrial power systems.
RCD (Residual Current Device) Protection: Enhanced safety features with built-in RCD, ensuring protection against electrical faults and maintaining the safety of the testing environment.
Precision Controls: Fine-tune load increments with precision, allowing for detailed testing and accurate performance analysis of power equipment.
Comprehensive Monitoring: Integrated digital displays provide real-time monitoring of voltage, current, power, and frequency, giving you complete control over the testing process.
Setup: Connect the load bank to the power source or generator you wish to test.
Load Application: Adjust the load settings on the load bank to apply the desired amount of load (up to 5 kW in your case).
Monitoring: The RCD will monitor for any electrical faults or leakage currents during the test and disconnect the load if unsafe conditions are detected.
Ventilation: Load banks can generate heat, so ensure they are used in a well-ventilated area.
Personal Protective Equipment (PPE): Always use appropriate PPE when operating electrical testing equipment.
Regular Maintenance: Ensure the load bank and RCD are regularly maintained and tested to ensure proper operation and safety.
Name | Three-Phase RCD load - Nonlinear load | |||||
Model | IMAX5330-15k | IMAX5330-30k | IMAX5330-45k | IMAX5330-60k | IMAX3510-100k | IMAX3510-200k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V | |||||
Working Voltage | Other voltages, wide voltages, or other mode can be customized | |||||
Max Power | 15kVA | 30kVA | 45kVA | 60kVA | 100kVA | 200kVA |
Rated Frequency | 50/60Hz | |||||
Power Factor (PF) | 0.6~1 adjustable,0.5 at least | |||||
Crest Factor(CF) | 2~3adjustable | |||||
Step accuracy | 100W/50W/25W Optional | |||||
· Load classification ·
| A Phase:0.1k/0.2k/0.5k/1k/2k/5k/other | |||||
B Phase:0.1k/0.2k/0.5k/1k/2k/5k/other | ||||||
C Phase:0.1k/0.2k/0.5k/1k/2k/5k/other | ||||||
Customizable: three single-phase/one single-phase/three-phase independent, maximum power does not exceed total power | ||||||
Load Function | R load test, RCD load test, total load switch, short circuit function is optional | |||||
Main Testing Items | Portable energy storage power supply, outdoor energy storage power supply, home energy storage power supply, photovoltaic inverter load test, UPS power supply test, other nonlinear load test requirements | |||||
Protection Alarm | Ground protection, high temperature fault, emergency stop and other protection functions. | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | |||||
Noise | ≤72dB | ≤75dB | ≤78dB | |||
Air Outlet Mode | Wind in from the side down and out from the top. | |||||
Display Accuracy | 0.1V,0.1A,PF(0.01) | |||||
Control Mode | Manual: Button/circuit breaker control | |||||
Local manual control: through 7 inch LCD touch screen of load bank | ||||||
Remote intelligent control: RS485, (the protocol is Modbus-RTU, and the upper computer software is provided.) | ||||||
Place of Use | Indoor | Indoor/Outdoor | ||||
Weight | 150kg | 230kg | 280kg | 320kg | 400kg | 480kg |
Size | W800mm×D600mm×H1600mm | W1000mm×D1200mm×H1850mm | W1200mm×D1400mm×H2000mm |
Name | Single-phase RCD load | ||
Model | IMAX5310-5k | IMAX5310-10k | IMAX3510-15k |
Rated Voltage | 1P2W,220V/110V,Double voltage can be customized | ||
Max Power | 5kVA | 10kVA | 15kVA |
Rated Frequency | 50/60Hz | ||
Power Factor (PF) | 0.6~1(adjustable),0.45 at least | ||
Crest Factor(CF) | 2~3 | ||
Step accuracy | 100W/50W/25W Optional | ||
Load classification | 0.1k/0.2k/0.5k/1k/2k/5k/other | ||
Main Testing Items | Portable energy storage power supply, outdoor energy storage power supply, home energy storage power supply, photovoltaic inverter load test, UPS power supply test, other nonlinear load test requirements | ||
Protection Alarm | Ground protection, high temperature fault, emergency stop and other protection functions. | ||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | ||
Noise | ≤65dB | ≤70dB | ≤70dB |
Air Outlet Mode | Wind in from the front, out from the behind | Wind in from the side down and out from the top | Wind in from the side down and out from the top |
Display Accuracy | 0.1V,0.1A | ||
Control Mode | Manual: Button/circuit breaker control | ||
Local manual control: through 7 inch LCD touch screen of load bank | |||
Remote intelligent control: RS485, (the protocol is Modbus-RTU, and the upper computer software is provided.) |
Home Technology Support About Us FAQ Factory Show Download Video List