R&D and Product Development: Ideal for manufacturers in the research and development phase of new charging pile designs, allowing for thorough testing before market release.
Production Line Testing: Ensures that charging piles meet specified performance criteria before leaving the factory, helping to maintain consistent product quality.
Field Service and Maintenance: Used by service teams for on-site testing and diagnostics of installed charging stations, ensuring optimal operation and identifying potential issues.
Compliance Testing: Supports regulatory compliance testing to ensure that charging piles meet local and international standards.
Power Capacity: 300KW (AC/DC)
Input Voltage Range: AC: 220V/380V, DC: 200V-1000V
Load Adjustment: Fine-tuned control, with step and continuous load adjustment
Cooling Method: Forced air/liquid cooling
Safety Features: Over-voltage, over-current, short-circuit protection, thermal management
Interface: Digital control panel with remote access capability
Data Logging: Integrated with real-time monitoring and data recording
The 300KW AC/DC Integrated Charging Pile Test Load Bank is an essential tool for any organization involved in the EV charging industry, offering unmatched flexibility, safety, and precision in testing high-power charging infrastructure.
Name | Single phase pure resistance load -R | ||
Model | IMAX3110-30k | IMAX3110-50k | IMAX3110-100k |
Rated Voltage | 1P2W,AC230V/220V/110V | ||
Resistive Power | 33kW | 55kW | 110kW |
Rated Frequency | 50/60Hz | 50/60Hz | 50/60Hz |
Loading Mode | Step and shift loading | ||
Load Characteristic | Pure Resistance | ||
Load Stepping | The minimum resistance step size is 0.1kW | ||
Main test items | Power supply detection long - term load, switching device life test | ||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | ||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | ||
Noise | ≤70dB | ≤73dB | ≤75dB |
Air Outlet Mode | Side wind in, side wind out | Wind in from the side down and out from the top. | |
Display Accuracy | 0.1V,0.1A | ||
Control Mode | Local manual control: Local button/air switch/touch screen control | ||
Remote intelligent control: RS485/CAN/ Ethernet | |||
Place of Use | Indoor | ||
Weight | 50kg | 75kg | 150kg |
Size | W600mm×D800mm×H800mm | W600mm×D800mm×H1400mm | W600mm×D800mm×H1600mm |
Name | Three-phase pure resistance load -R | |||||
Model | IMAX3130-50k | IMAX3130-100k | IMAX3130-300k | IMAX3130-500k | IMAX3130-700k | IMAX3130-1000k |
Rated Voltage | 3P4W,AC220V/380V/400V/415V/440V | |||||
Resistive Power | 55kW | 110kW | 310kW | 510kW | 710kW | 1030kW |
Rated Frequency | 50/60Hz | |||||
Loading Mode | Step loading | |||||
Load Characteristic | pure resistance | |||||
Load Stepping | The minimum step size of the resistance divider is 10W | |||||
Main test items | Power supply detection long - term load, switching device life test | |||||
Protection Alarm | Load short circuit, over current protection, over voltage protection, high temperature fault, emergency stop and other protection functions. | |||||
Measurement and Control Parameter | Display voltage, current, active power, reactive power, apparent power, power factor, frequency and other basic functions. | |||||
Noise | ≤75dB | ≤79dB | ≤82dB | |||
Air Outlet Mode | Wind in from the side down and out from the top | Side down ejection/side in side out | Wind in from the side down and out from the top | |||
Display Accuracy | 0.1V,0.1A | |||||
Control Mode | Local manual control: local button/circuit breaker | Local manual control: through the load box 7 inch LCD touch screen. | ||||
Remote intelligent control: RS485/CAN/ Ethernet | Remote intelligent control: RS485/CAN/ Ethernet | |||||
Place of Use | Indoor | Indoor/Outdoor | ||||
Weight | 80kg | 120kg | 450kg | 650kg | 950kg | 1300kg |
Size | W600mm×D800mm×H1400mm | W600mm×D800mm×H1600mm | · sideward :W1500mm×D1300mm×H1400mm ejection:W1200mm*D1200mm*1800mm | sideward :W1750mm×D1300mm×H1400mm | W1200mm×D1400mm×H2000mm | W1800mm×D1200mm×H2000mm |
Home Technology Support About Us FAQ Factory Show Download Video List